E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ERRORDOWN

ERRORDOWN

Errordown_1.3.6.1.4.1.2011.5.25.257.2.1 hwErrordown

Description

Error-down occurred. (Ifindex=[INTEGER], Ifname=[STRING], Cause=[STRING])

The alarm was generated when an errordown event occurred.

Attributes

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.257.2.1

Trap severity

Warning

Match trap

Errordown_1.3.6.1.4.1.2011.5.25.257.2.2 hwErrordownRecovery

Parameters

Parameter

Description

IfIndex

Index of an interface

Ifname

Interface name

Cause

Cause of the errordown event

Impact on the System

After the errordown event occurs, traffic cannot be forwarded on relevant interfaces and services are interrupted.

Possible Causes

bpdu-protection.(The MSTP edge port received BPDU packets.)

Procedure
  1. Locate the fault based on the value of the Cause field in the alarm.

If the value of the Cause field is bpdu-protection, go to Step 2.

  1. Check whether the interface is specified as an edge port.

    • If the interface is not specified as an edge port, go to Step 3.
    • If the interface is specified as an edge port, go to Step 4.

  2. Perform the following steps.

    • Run:
      interface interface-type interface-num

      The interface view is displayed.

    • Run:
      undo stp edged-port and undo shutdown

      The edge port configuration is removed. Check whether the log still exists. If the log still exists, go to Step 4.

  3. Collect log messages and contact Huawei technical support personnel.

Errordown_1.3.6.1.4.1.2011.5.25.257.2.2 hwErrordownRecovery

Description

Error-down recovered. (Ifindex=[INTEGER], Ifname=[STRING], Cause=[STRING], RecoverType=[STRING])

The error-down fault recovered.

Attributes

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.257.2.2

Trap severity

Warning

Match trap

Errordown_1.3.6.1.4.1.2011.5.25.257.2.1 hwErrordown

Parameters

Parameter

Description

IfIndex

Index of an interface

Ifname

Interface name

Cause

Cause of an alarm

RecoverType

Recovery type: automatic recovery or recovery using the command undo shutdown (interface view) or command restart (interface view).

Impact on the System

This log message is informational only, and no action is required.

Possible Causes
  1. Cause 1: bpdu-protection, manual recovery.(manual recovery.)
  2. Cause 2: bpdu-protection, auto recovery.(automatic recovery.)
Procedure
  • This log message is informational only, and no action is required.