E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
HUAWEI-SYS-MAN

HUAWEI-SYS-MAN

HUAWEI-SYS-MAN_1.3.6.1.4.1.2011.5.25.19.2.1 hwSysClockChangedNotification

Description

System clock changed.

The system clock changed.

Attributes

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.19.2.1

Trap severity

Info

Parameters

None

Impact on the System

Services are not affected.

Possible Causes

The system clock changed.

Procedure
  • The log is informational only, and no action is required.

HUAWEI-SYS-MAN_1.3.6.1.4.1.2011.5.25.19.2.2 hwSysReloadNotification

Description

Reload operation completed.

The system restarted the image file.

Attributes

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.19.2.2

Trap severity

Info

Parameters

None

Impact on the System

Services are not affected.

Possible Causes

The system succeeded in restarting the image file.

Procedure
  • The log is informational only, and no action is required.

HUAWEI-SYS-MAN_1.3.6.1.4.1.2011.5.25.19.2.11 hwPatchInstallFail

Description

Patch package installation failed. (SlotIndex=[SlotIndex], PatchIndex=[PatchIndex], PackageName=[PackageName], PackageVersion=[PackageVersion], FailReason=[FailReason])

The patch failed to be installed.

Attributes

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.19.2.11

Trap severity

Critical

Match trap

Clear-alarm trap: HUAWEI-SYS-MAN_1.3.6.1.4.1.2011.5.25.19.2.12 hwPatchInstallFailClear

Parameters

Parameter

Description

SlotIndex

Indicates the index of the device on which the patch installation failed.

PatchIndex

Indicates the patch index.

PackageName

Indicates the patch name.

PackageVersion

Indicates the patch version.

FailReason

Indicates the reason for patch installation failure.

Impact on the System

Services are not affected.

Possible Causes

Cause 1: Failed to read the configuration information of the patch package.

Cause 2: Failed to get the patch package.

Cause 3: There was insufficient memory space for the patch package.

Cause 4: The patch conflicted with the previous one.

Cause 5: The patch package version was incorrect.

Procedure
  • Cause 1: Failed to read the configuration information of the patch package.
    1. Re-install the patch package. After the installation is complete, run the display patch-information command to check the patch package status.
      • If the status is run, the patch package has been successfully installed and no action is required.
      • If the status is not run, go to Step 2.
    2. Collect the alarm information, log information, and configurations, and then contact the Huawei technical support personnel.
  • Cause 2: Failed to get the patch package.
    1. Collect the alarm information, log information, and configurations, and then contact the Huawei technical support personnel.
  • Cause 3: There was insufficient memory space for the patch package.
    1. Collect the alarm information, log information, and configurations, and then contact the Huawei technical support personnel.
  • Cause 4: The patch conflicted with the previous one.
    1. Collect the alarm information, log information, and configurations, and then contact the Huawei technical support personnel.
  • Cause 5: The patch package version was incorrect.
    1. Collect the alarm information, log information, and configurations, and then contact the Huawei technical support personnel.

HUAWEI-SYS-MAN_1.3.6.1.4.1.2011.5.25.19.2.12 hwPatchInstallFailClear

Description

The patch-installation failure alarm is cleared. (SlotIndex=[SlotIndex], PatchIndex=[PatchIndex], PackageName=[PackageName], PackageVersion=[PackageVersion], FailReason=[FailReason])

The patch-installation failure alarm was cleared.

Attributes

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.19.2.11

Trap severity

Critical

Match trap

Clear-alarm trap: HUAWEI-SYS-MAN_1.3.6.1.4.1.2011.5.25.19.2.11 hwPatchInstallFail

Parameters

Parameter

Description

SlotIndex

Indicates the index of the device on which the patch installation failed.

PatchIndex

Indicates the patch index.

PackageName

Indicates the patch name.

PackageVersion

Indicates the patch version.

FailReason

Indicates the reason for patch installation failure.

Impact on the System

Services are not affected.

Possible Causes

The patch-installation failure alarm was cleared.