E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RMON

RMON

RMON_1.3.6.1.2.1.16.0.1 risingAlarm

Description

Alarm table [AlarmId] monitors [OID] with the sample type being [SampleType], and the sampled alarm value [SampleValue] is greater than or equal to [Threshold].

Attributes

Attributes

Description

Trap OID

1.3.6.1.2.1.16.0.1

Trap severity

Warning

Match trap

RMON_1.3.6.1.2.1.16.0.2 fallingAlarm

Parameters

Name

Meaning

oid

OID of an alarm

alarm-table-index

Index of an alarm table

sample-object-oid

OID of a sampled object

sample-type

Type of a sampled alarm

alarm-value

Alarm value

rising-value

Upper threshold of an alarm

Impact on the System

The system is not affected.

Possible Causes

Cause 1:

The current sampled value was greater than or equal to the upper threshold and the previous sampled value was less than the upper threshold.

Cause 2:

This alarm entry became valid, and the first sampled value was greater than or equal to the upper threshold.

Procedure
  1. This trap message is informational only, and no action is required.

RMON_1.3.6.1.2.1.16.0.2 fallingAlarm

Description

Alarm table [AlarmId] monitors [OID] with the sample type being [SampleType], and the sampled alarm value [SampleValue] is greater than or equal to [Threshold].

Attribute

Attributes

Description

Trap OID

1.3.6.1.2.1.16.0.2

Trap severity

Warning

Match trap

RMON_1.3.6.1.2.1.16.0.1 risingAlarm

Parameters

Name

Meaning

oid

OID of an alarm

alarm-table-index

Index of an alarm table

sample-object-oid

OID of a sampled object

sample-type

Type of a sampled alarm

alarm-value

Alarm value

falling-value

Lower threshold of an alarm

Impact on the System

The system is not affected.

Possible Causes

Cause 1:

The current sampled value was less than or equal to the lower threshold, and the previous sampled value was greater than the lower threshold.

Cause 2:

The alarm table became valid, and the first sampled value was less than or equal to the lower threshold.

Procedure
  1. This trap message is informational only, and no action is required.