E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SMLKTRAP

SMLKTRAP

SMLKTRAP_1.3.6.1.4.1.2011.5.25.42.5.2.1 hwSmartLinkLinkSwitch

Description

Smart link group [SmlkGrpID] status turned to [SmlkGrpStatus].

The status of the Smart Link group changed.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwSmartLinkLinkSwitch

Trap OID

1.3.6.1.4.1.2011.5.25.42.5.2.1

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter

Description

SmlkGrpID

Indicates the ID of a Smart Link group.

SmlkGrpStatus

Indicates the status of a Smart Link group.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.42.5.1.8.1.4

hwSmartLinkGcGroupStatus

hwSmartLinkGcGroupStatus

Impact on the System
  • If the status changed because a Smart Link group is enabled, the system will not be affected.
  • If the status changed because a Smart Link group is disabled, the system will not be affected.
  • If the status changed because a link switchover is performed in a Smart Link group, traffic forwarding may be affected.
Possible Causes

Cause 1: The smart link group is enabled.

Cause 2: The smart link group is disabled.

Cause 3: The link of smart link group is switched.

Procedure
  • Cause 1: The smart link group is enabled.

    The alarm is informational only, and no action is required.

  • Cause 2: The smart link group is disabled.

    The alarm is informational only, and no action is required.

  • Cause 3: The link of smart link group is switched.
    • If a link switchover is performed manually, the alarm is informational only, and no action is required.
    • If a link switchover is performed automatically, the primary link fails and perform the following steps:
  1. Run the display interface brief command to check the physical status of the master interface on the primary link.
  2. Check whether the cable of the primary link is correctly connected.
  • If the master interface is Up, and the cable is correctly connected, go to Step 3.
  • If the master interface goes Down, and the undo shutdown command does not set the interface to Up, go to Step 3.
  1. Collect trap, log, and configuration information, and contact technical support personnel.

SMLKTRAP_1.3.6.1.4.1.2011.5.25.42.5.2.2 hwSmartLinkInactiveLinkFail

Description

[LinkStatus] link port [IfIndex] of smart link group [SmlkGrpID] was abnormal.

A member interface in a Smart Link group was faulty.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwSmartLinkInactiveLinkFail

Trap OID

1.3.6.1.4.1.2011.5.25.42.5.2.2

Alarm ID

0x09c72000

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

SMLKTRAP_1.3.6.1.4.1.2011.5.25.42.5.2.3 hwSmartLinkInactiveLinkResume

Parameters

Parameter

Description

LinkStatus

Indicates the status of a link.

IfIndex

Indicates the index of an interface.

SmlkGrpID

Indicates the ID of a Smart Link group that an interface belongs.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.42.5.1.9.1.3

hwSmartLinkPcIfIndex

hwSmartLinkPcIfIndex

Impact on the System

The inactive interface is faulty, and no link switchover can be performed.

Possible Causes

Cause: The inactive interface is down.

Procedure
  • The inactive interface is down.
    1. Run the display interface brief command to check the physical status of the inactive interface.
    2. Check whether the cable of the inactive link is correctly connected.
      • If the inactive interface is Up, and the cable is correctly connected, go to Step 3.
      • If the inactive interface goes Down, and the undo shutdown command does not set the interface to Up, go to Step 3.
    3. Collect trap, log, and configuration information, and contact technical support personnel.

SMLKTRAP_1.3.6.1.4.1.2011.5.25.42.5.2.3 hwSmartLinkInactiveLinkResume

Description

[LinkStatus] link port [IfIndex] of smart link group [SmlkGrpID] was normal.

A member interface in a Smart Link group recovered.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwSmartLinkInactiveLinkResume

Trap OID

1.3.6.1.4.1.2011.5.25.42.5.2.3

Alarm ID

0x09c72000

Alarm Type

communicationsAlarm

Raise or Clear

Clear

Match trap

SMLKTRAP_1.3.6.1.4.1.2011.5.25.42.5.2.2 hwSmartLinkInactiveLinkFail

Parameters

Parameter

Description

LinkStatus

Indicates the status of a link.

IfIndex

Indicates the index of an interface.

SmlkGrpID

Indicates the ID of a Smart Link group that an interface belongs.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.42.5.1.9.1.3

hwSmartLinkPcIfIndex

hwSmartLinkPcIfIndex

Impact on the System

The system will not be affected.

Possible Causes

Cause: The member interface of smart link group is up.

Procedure
  • The alarm is informational only, and no action is required.

SMLKTRAP_1.3.6.1.4.1.2011.5.25.42.5.2.4 hwSmartLinkGroupEnable

Description

Smart link group [SmlkGrpID] was [EnabledStatus].

A Smart Link group was enabled.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwSmartLinkGroupEnable

Trap OID

1.3.6.1.4.1.2011.5.25.42.5.2.4

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter

Description

SmlkGrpID

Indicates the ID of a Smart Link group.

EnabledStatus

Indicates whether a Smart Link group is enabled.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.42.5.1.8.1.5

hwSmartLinkGcEnable

hwSmartLinkGcEnable

Impact on the System

The system will not be affected.

Possible Causes

Cause: The smart link group is enabled.

Procedure
  • The alarm is informational only, and no action is required.

SMLKTRAP_1.3.6.1.4.1.2011.5.25.42.5.2.5 hwSmartLinkGroupDisable

Description

Smart link group [SmlkGrpID] was [EnabledStatus].

A Smart Link group was disabled.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwSmartLinkGroupDisable

Trap OID

1.3.6.1.4.1.2011.5.25.42.5.2.5

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter

Description

SmlkGrpID

Indicates the ID of a Smart Link group.

EnabledStatus

Indicates whether a Smart Link group is enabled.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.42.5.1.8.1.5

hwSmartLinkGcEnable

hwSmartLinkGcEnable

Impact on the System

The system will not be affected.

Possible Causes

Cause: The smart link group is disabled.

Procedure
  • The alarm is informational only, and no action is required.
Translation