E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG

STACKMNG

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.1 hwStackLinkUp

Description

The interface Stack-Port is up. (StackPortName=Stack-Port[hwStackPortStackId]/[hwStackPortId])

The stack interface became Up.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Notice

Mnemonic Code

hwStackLinkUp

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.1

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Name

Meaning

StackPortName

Indicates the name of a stack interface.

hwStackPortStackId

Indicates the stack ID of the device where the stack interface locates.

hwStackPortId

Indicates the ID of a stack interface.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.21.1.1

hwStackPortStackId

hwStackPortStackId;

hwStackPortId;

1.3.6.1.4.1.2011.5.25.183.1.21.1.2

hwStackPortId

hwStackPortStackId;

hwStackPortId;

1.3.6.1.4.1.2011.5.25.183.1.21.1.5

hwStackPortStatus

hwStackPortStackId;

hwStackPortId;

Impact on the System

A stack can be created successfully.

Possible Causes

The status of the link protocol became Up after a stack was established.

Procedure
  1. This log message is informational only, and no action is required.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.2 hwStackLinkDown

Description

The interface Stack-Port is down. (StackPortName=Stack-Port[hwStackPortStackId]/[hwStackPortId])

The stack interface became Down.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackLinkDown

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.2

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Name

Meaning

StackPortName

Indicates the name of a stack interface.

hwStackPortStackId

Indicates the stack ID of the device where the stack interface locates.

hwStackPortId

Indicates the ID of a stack interface.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.21.1.1

hwStackPortStackId

hwStackPortStackId;

hwStackPortId;

1.3.6.1.4.1.2011.5.25.183.1.21.1.2

hwStackPortId

hwStackPortStackId;

hwStackPortId;

1.3.6.1.4.1.2011.5.25.183.1.21.1.5

hwStackPortStatus

hwStackPortStackId;

hwStackPortId;

Impact on the System

A stack fails to be created or splits.

Possible Causes
  • The stack interface was shut down.
  • All physical interfaces became Down.
  • The stack link was faulty.
Procedure
  1. Check the connection and validity of stack cables. Run the display interface brief command to check the physical status and protocol status of the stack interface.
  • If the physical status of an interface is Down, check whether the cable connected to the interface is loosened or removed.
  • If the physical status of the interface is Up, go to step 2.
  1. Check whether the shutdown command was executed on the interface. Run the interface interface-type interface-number command to enter the stack interface view, and run the display this command to check whether the shutdown configuration exists.

    • If so, run the undo shutdown command.
    • If not, go to step 3.

  2. Collect traps, logs, and configurations, and contact technical support personnel.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.9 hwStackLogicStackPortLinkErr

Description

The interface Stack-Port was linked invalidly. (hwStackLocalIfName=[hwStackLocalIfName], hwStackPeerIfName=[hwStackPeerIfName], Reason=[Reason])

Physical member ports of the stack port were connected incorrectly.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwStackLogicStackPortLinkErr

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.9

Alarm ID

0x09a20010

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.13 hwStackLogicStackPortLinkErrResume

Parameters

Name

Meaning

hwStackLocalIfName

Indicates the name of the local stack port.

hwStackPeerIfName

Indicates the name of the peer stack port.

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.1

hwStackLocalIfName

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.2

hwStackPeerIfName

N/A

Impact on the System

The stack cannot be created. Stack members were removed, and the stack split.

Possible Causes
  • Cable connection of physical member ports caused a loop.
  • Physical member ports of a local stack port connected to those of two stack ports on the remote device.
  • Physical member ports of a local stack port connected to those of stack ports on different remote devices.
  • The member port of Stack-Port is connected to a common service port.
Procedure
  1. Run the display interface brief command to enter the stack port view, and check whether physical ports of the same stack port are connected.
  • If so, disconnect the ports.
  • If not, go to step 2.
  1. Check whether physical ports of the stack port are connected to a different device.

    • If so, check the protocol status of these ports. Remove the cables that connect the ports whose physical status is Up but protocol status is Down.
    • If not, go to step 3.

  2. Check whether any physical port of the same stack port is connected to another stack port on the same device.

    • If so, run the display stack topology command to check the stack ID of the device that the stack port is connected to. Remove the cables that connect the ports to another device.
    • If not, go to step 4.

  3. Check whether the physical member ports are connected to common service ports.

    • If so, remove the incorrectly connected links or change the ports on both ends of the links to the same mode (stack or common service port mode).
    • If not, go to step 5.

  4. Collect traps, logs, and configurations, and contact technical support personnel.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.11 hwPhyStackPortIsDown

Description

The stack member port's link state is down. (hwStackLocalIfName=[hwStackLocalIfName])

The physical member interfaces of the stack interface became Down.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwPhyStackPortIsDown

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.11

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Name

Meaning

hwStackLocalIfName

Indicates the name of the local interface.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.1

hwStackLocalIfName

N/A

Impact on the System

A stack fails to be created or splits.

Possible Causes

Cause 1: Physical member interfaces of the stack interface became Down.

Cause 2: Physical member interfaces of the stack interface were shut down.

Cause 3. The stack link was faulty.

Procedure
  1. Check the connection and validity of stack cables. Run the display interface brief command to check the physical status and protocol status of the stack interface.
  • If the physical status of an interface is Down, check whether the cable connected to the interface is loosened or removed.
  • If the physical status of the interface is Up, go to step 2.
  1. Check whether the shutdown command was executed on the interface. Run the interface interface-type interface-number command to enter the stack interface view, and run the display this command to check whether the shutdown configuration exists.

    • If so, run the undo shutdown command.
    • If not, go to step 3.

  2. Collect traps, logs, and configurations, and contact technical support personnel.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.12 hwPhyStackPortIsUp

Description

The stack member port's link state is up. (hwStackLocalIfName=[hwStackLocalIfName])

The physical member interfaces of the stack interface became Up.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Notice

Mnemonic Code

hwPhyStackPortIsUp

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.12

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Name

Meaning

hwStackLocalIfName

Indicates the name of the local interface.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.1

hwStackLocalIfName

N/A

Impact on the System

A stack can be created successfully.

Possible Causes

A stack was created successfully, and the physical member interfaces of the stack interface became Up.

Procedure
  1. This trap message is informational only, and no action is required.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.13 hwStackLogicStackPortLinkErrResume

Description

The interface Stack-Port was linked invalidly resume. (hwStackLocalIfName=[hwStackLocalIfName], hwStackPeerIfName=[hwStackPeerIfName], Reason=[Reason])

The fault in physical member interface connection was rectified.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwStackLogicStackPortLinkErrResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.13

Alarm ID

0x09a20010

Alarm Type

environmentalAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.9 hwStackLogicStackPortLinkErr

Parameters

Name

Meaning

hwStackLocalIfName

Indicates the name of the local stack port.

hwStackPeerIfName

Indicates the name of the peer stack port.

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.1

hwStackLocalIfName

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.2

hwStackPeerIfName

N/A

Impact on the System

The stack link fault is rectified, and the stack can be created successfully.

Possible Causes

Physical member interfaces of the stack interface were connected correctly.

Procedure
  1. This trap message is informational only, and no action is required.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.15 hwStackLinkLimitAlarm

Description

The number of STACK links has reached the alarm threshold. (hwStackLocalIfName=[hwStackLocalIfName], hwStackCurrentLinkNum=[hwStackCurrentLinkNum], hwStackLinkAlarmThreshold=[hwStackLinkAlarmThreshold])

The number of available stack links is smaller than the alarm threshold.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackLinkLimitAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.15

Alarm ID

0x09a22014

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.16 hwStackLinkLimitAlarmResume

Parameters

Parameter

Description

hwStackLocalIfName

Specifies the name of a stack port.

hwStackCurrentLinkNum

Specifies the number of available physical member ports in a stack port.

hwStackLinkAlarmThreshold

Specifies the alarm threshold for the number of stack links.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.1

hwStackLocalIfName

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.14

hwStackCurrentLinkNum

N/A

1.3.6.1.4.1.2011.5.25.183.1.8

hwStackLinkAlarmThreshold

N/A

Impact on the System

Stack link bandwidth and reliability are reduced, and even stack split may occur.

Possible Causes

Some stack links become faulty, causing the number of available stack links to be smaller than the alarm threshold.

Procedure
  1. Run the display interface brief command to check information and status of physical member ports in a stack port.
  • If some physical member ports are Down, check whether their cables are loose.
  • If all physical member ports are Up, go to step 2.
  1. Increase the number of physical member ports in the stack port or run the stack port-link threshold command to set the alarm threshold of stack links to a larger value.
  2. Collect trap messages, log messages, and configurations, and then contact technical support personnel.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.16 hwStackLinkLimitAlarmResume

Description

The number of STACK links has reached the alarm threshold resume. (hwStackLocalIfName=[hwStackLocalIfName], hwStackCurrentLinkNum=[hwStackCurrentLinkNum], hwStackLinkAlarmThreshold=[hwStackLinkAlarmThreshold])

The number of available stack links is larger than or equal to the alarm threshold.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackLinkLimitAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.16

Alarm ID

0x09a22014

Alarm Type

equipmentAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.15 hwStackLinkLimitAlarm

Parameters

Parameter

Description

hwStackLocalIfName

Specifies the name of a stack port.

hwStackCurrentLinkNum

Specifies the number of available physical member ports in a stack port.

hwStackLinkAlarmThreshold

Specifies the alarm threshold for the number of stack links.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.1

hwStackLocalIfName

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.14

hwStackCurrentLinkNum

N/A

1.3.6.1.4.1.2011.5.25.183.1.8

hwStackLinkAlarmThreshold

N/A

Impact on the System

None

Possible Causes

Physical member ports recover from faults.

Procedure
  1. This trap message is informational only, and no action is required.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.18 hwStackFabricPortLinkErr

Description

The interface Fabric-Port was linked invalidly. (hwStackFabricPort=[hwStackFabricPort], hwStackFabricMemberPort=[hwStackFabricMemberPort], hwStackPeerPort=[hwStackPeerPort], Reason=[Reason])

The Fabric ports in the SVF are incorrectly connected.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwStackFabricPortLinkErr

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.18

Alarm ID

0x09a22016

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.19 hwStackFabricPortLinkErrResume

Parameters

Parameter

Meaning

hwStackFabricPort

Indicates the Fabric port.

hwStackFabricMemberPort

Indicates the member port of the Fabric port.

hwStackPeerPort

Indicates the peer port.

Reason

Indicates the alarm cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.8

hwStackFabricPort

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.9

hwStackFabricMemberPort

N/A

Impact on the System

The SVF links are unavailable, and the SVF may fail to be established.

Possible Causes

Cause 1: One Fabric port is connected to more than one leaf switch.

Cause 2: The Fabric ports on the spine switch are connected to each other.

Cause 3: One leaf switch is connected to more than one Fabric port.

Cause 4: The member port of a Fabric port is connected to an isolated port.

Cause 5: The member port of a Fabric port is connected to the member port of a stack port.

Cause 6: A leaf switch is connected to multiple stack systems.

Procedure
  1. Run the display interface brief command to view the member ports of the Fabric port and check whether the member ports are connected.
  • If so, disconnect the ports.
  • If not, go to step 2.
  1. Check whether one Fabric port is connected to only one leaf switch and whether the leaf switch is only connected to this Fabric port.

    • If so, go to step 3.
    • If not, modify the connections based on rules.

  2. Collect traps, logs, and configurations, and contact technical support personnel.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.19 hwStackFabricPortLinkErrResume

Description

The interface Fabric-Port was linked invalidly resume. (hwStackFabricPort=[hwStackFabricPort], hwStackFabricMemberPort=[hwStackFabricMemberPort], hwStackPeerPort=[hwStackPeerPort], Reason=[Reason])

The fault that the Fabric ports in the SVF are incorrectly connected is rectified.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwStackFabricPortLinkErrResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.19

Alarm ID

0x09a22016

Alarm Type

environmentalAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.18 hwStackFabricPortLinkErr

Parameters

Parameter

Meaning

hwStackFabricPort

Indicates the Fabric port.

hwStackFabricMemberPort

Indicates the member port of the Fabric port.

hwStackPeerPort

Indicates the peer port.

Reason

Indicates the alarm cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.8

hwStackFabricPort

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.9

hwStackFabricMemberPort

N/A

Impact on the System

The SVF links are recovered, and the SVF can be established.

Possible Causes

The Fabric ports are correctly connected.

Procedure
  1. This log message is informational only, and no action is required.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.20 hwStackLeafSingleHomedAlarm

Description

The leaf switch is only linked to one spine switch.(hwStackMemberId=[hwStackMemberId], hwStackLeafMemberId=[hwStackLeafMemberId])

The leaf switch is connected to only one spine switch.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackLeafSingleHomedAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.20

Alarm ID

0x09a22017

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.21 hwStackLeafSingleHomedAlarmResume

Parameters

Parameter

Meaning

hwStackMemberId

ID of the spine switch.

hwStackLeafMemberId

ID of the leaf switch.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.10

hwStackMemberId

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.11

hwStackLeafMemberId

N/A

Impact on the System

The system reliability is reduced.

Possible Causes

The leaf switch is connected to only one spine switch.

Procedure
  1. Connect the leaf switch to multiple spine switches.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.21 hwStackLeafSingleHomedAlarmResume

Description

The leaf switch is only linked to one spine switch resume. (hwStackMemberId=[hwStackMemberId], hwStackLeafMemberId=[hwStackLeafMemberId])

The trap indicating that the leaf switch is connected to only one spine switch is cleared.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackLeafSingleHomedAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.21

Alarm ID

0x09a22017

Alarm Type

environmentalAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.20 hwStackLeafSingleHomedAlarm

Parameters

Parameter

Meaning

hwStackMemberId

ID of the spine switch.

hwStackLeafMemberId

ID of the leaf switch.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.10

hwStackMemberId

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.11

hwStackLeafMemberId

N/A

Impact on the System

The system reliability is improved.

Possible Causes

The leaf switch is connected to multiple spine switches.

Procedure
  1. This log message is informational only, and no action is required.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.22 hwStackMemberLimit

Description

The number of stack members has reached the upper limit and new members failed to join. (hwStackMemberThreshold=[hwStackMemberThreshold])

The number of stack members has reached the upper limit and new members failed to join.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackMemberLimit

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.22

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter

Meaning

hwStackMemberThreshold

Maximum number of stack members.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.9

hwStackMemberThreshold

N/A

Impact on the System

Some devices cannot join the stack system.

Possible Causes

The number of stack members reaches the upper limit.

Procedure
  1. Check whether the stack members join or are merged due to incorrect connections.

    • If yes, reconnect the links.
    • If no, remove excess stack member devices.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.23 hwStackMemberAdd

Description

The stack member device joined in. (hwStackIdIndex=[hwStackIdIndex], hwStackId=[hwStackId], hwStackMacAddress=[hwStackMacAddress])

The stack member device joined in.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackMemberAdd

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.23

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter

Meaning

hwStackIdIndex

ID index of the stack member.

hwStackId

ID of the stack member.

hwStackMacAddress

MAC address of the device.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.25.1.6

hwStackId

hwStackIdIndex

Impact on the System

A new member device joins the stack system.

Possible Causes

A new member device joins the stack system.

Procedure
  1. Check whether the member device is added manually.
  • If so, no action is required.
  • If no, go to step 2.
  1. Run the display stack configuration command to check whether the stack configuration complies with the requirement.

    • If so, go to step 3.
    • If no, modify the stack configuration and remove excess stack member devices.

  2. Collect trap messages, log messages, and configurations, and then contact technical support personnel.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.24 hwStackMemberLeave

Description

The stack member device left. (hwStackIdIndex=[hwStackIdIndex], hwStackId=[hwStackId], hwStackMacAddress=[hwStackMacAddress])

The stack member device left.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackMemberLeave

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.24

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter

Meaning

hwStackIdIndex

ID index of the stack member.

hwStackId

ID of the stack member.

hwStackMacAddress

MAC address of the device.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.25.1.6

hwStackId

hwStackIdIndex

Impact on the System

The stack is split or the member leaves the stack system.

Possible Causes

The member device leaves the stack system.

Procedure
  1. Check whether the member device is deleted manually from the stack system.
  • If so, no action is required.
  • If no, go to step 2.
  1. Run the display interface brief command to check whether the stack interface is Down.

    • If so, rectify the fault.
    • If no, go to step 3.

  2. Run the display stack configuration command to check whether the stack configuration complies with the requirement.

    • If so, go to step 4.
    • If no, modify the stack configuration.

  3. Collect trap messages, log messages, and configurations, and then contact technical support personnel.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.25 hwStackConfigDifferent

Description

The stack configuration is inconsistent. (hwStackId=[hwStackId], hwStackReason=[hwStackReason])

The current stack configuration is inconsistent with the stack configuration for next startup.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackConfigDifferent

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.25

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter

Description

hwStackId

Stack member ID.

hwStackReason

Alarm cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.25.1.6

hwStackId

hwStackIdIndex

1.3.6.1.4.1.2011.5.25.183.1.32.12

hwStackReason

N/A

Impact on the System

When the stack system starts, the stack may fail to be set up.

Possible Causes

1: The offline configuration of a newly added device exists on the master switch, is inconsistent with the current configuration, and is used as the configuration for next startup.

2: The stack configuration is manually modified to be inconsistent with the stack configuration for next startup.

Procedure
  1. Run the display stack configuration command to check whether the current stack configuration is consistent with the stack configuration for next startup. If not, manually modify the stack configuration.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.26 hwStackLeafConfigConflict

Description

Configuration exists on the uplink port of the leaf switch, and this port cannot be used as the fabric port. (hwStackLeafPort=[hwStackLeafPort])

The uplink port of the leaf switch has service configuration that conflicts with the SVF system on the parent switch, and so this port cannot be used as a member port of the fabric port.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackLeafConfigConflict

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.26

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter

Description

hwStackLeafPort

Uplink port number of the leaf switch.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.13

hwStackLeafPort

N/A

Impact on the System

Leaf switches cannot be added to the SVF system.

Possible Causes

The uplink port of the leaf switch has service configuration that conflicts with the SVF system on the parent switch

Procedure
  1. Manually delete common service configuration from the uplink port.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.27 hwStackChipSingleHomedAlarm

Description

In the dual-homing network, two ports of any chip on the dual-chip leaf switch are connected to a spine switch. (hwStackLeafMemberId=[hwStackLeafMemberId], Reason=[Reason])

When a CE5810-48T4S-EI is dual-homed to two parent switches, two ports of a forwarding chip are connected to the same parent switch.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackChipSingleHomedAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.27

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter

Meaning

hwStackLeafMemberId

Indicates the ID of the leaf switch.

Reason

Indicates the alarm cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.11

hwStackLeafMemberId

N/A

Impact on the System

Uplink traffic of leaf switches may be forwarded through the stack link of the parent switch.

Possible Causes

When a CE5810-48T4S-EI is dual-homed to two parent switches, two ports of a forwarding chip are connected to the same parent switch. 10GE1/17/1 and 10GE1/17/2 reside on the same forwarding chip; 10GE1/17/3 and 10GE1/17/4 reside on the same forwarding chip.

Procedure
  1. Connect the two ports on the same forwarding chip to different parent switches.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.28 hwStackChipSingleHomedAlarmResume

Description

In the dual-homing network, two ports of any chip on the dual-chip leaf switch are not connected to a spine switch. (hwStackLeafMemberId=[hwStackLeafMemberId], Reason=[Reason])

On dual-homing networking, two ports of a forwarding chip on the CE5810-48T4S-EI are not connected to the same parent switch.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackChipSingleHomedAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.28

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter

Meaning

hwStackLeafMemberId

Indicates the ID of the leaf switch.

Reason

Indicates the alarm cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.11

hwStackLeafMemberId

N/A

Impact on the System

Uplink traffic of the leaf switch is forwarded normally.

Possible Causes

Uplink line connection of the leaf switch is correct.

Procedure
  1. This log message is informational only, and no action is required.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.29 hwStackLeafMemberAdd

Description

The leaf member device joined in. (hwStackId=[hwStackId])

The leaf switch joined in SVF.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackLeafMemberAdd

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.29

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter

Meaning

hwStackId

ID of the leaf switch.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.25.1.6

hwStackId

hwStackIdIndex

Impact on the System

A new leaf switch joins the SVF system.

Possible Causes

A new leaf switch joins the SVF system.

Procedure
  1. Check whether the leaf switch is added manually.
  • If yes, no action is required.
  • If no, go to step 2.
  1. Run the display stack configuration command to check whether the SVF configuration complies with the requirement.

    • If yes, go to step 3.
    • If no, modify the SVF configuration and remove excess leaf switches.

  2. Collect trap messages, log messages, and configurations, and then contact technical support personnel.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.30 hwFabricLinkLimitAlarm

Description

The number of current fabric links is smaller than the number of fabric links configured. (hwStackFabricPort=[hwStackFabricPort], hwFabricCurrentLinkNum=[hwFabricCurrentLinkNum], hwFabricConfiguredLinkNum=[hwFabricConfiguredLinkNum])

The number of available fabric port links is smaller than the configured alarm threshold.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwFabricLinkLimitAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.30

Alarm ID

0x09da2003

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.31 hwFabricLinkLimitAlarmResume

Parameters

Name

Meaning

hwStackFabricPort

Indicates the fabric port number.

hwFabricCurrentLinkNum

Indicates the number of current links.

hwFabricConfiguredLinkNum

Indicates the configured alarm threshold.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.8

hwStackFabricPort

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.15

hwFabricCurrentLinkNum

N/A

1.3.6.1.4.1.2011.5.25.183.1.27.1.5

hwFabricConfiguredLinkNum

hwFabricPortIndex

Impact on the System

The downlink service port of the leaf switch connected to the fabric port will enter the error-down state.

Possible Causes

Cause 1: The networking is improper or the configured alarm threshold for the number of available fabric port links is high.

Cause 2: The protocol state of the port is Down.

Cause 3: The fabric port link is faulty.

Procedure
  1. Run the display stack link-state last-down-reason command to check whether a fabric port link is Down.
  • If a fabric port link is Down, rectify the fault according to the reason.
  • If all fabric port links are Up, go to step 2.
  1. Increase the number of fabric port links or run the fabric min-links threshold alarm-threshold command to reduce the alarm threshold for the number of available fabric port links.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.31 hwFabricLinkLimitAlarmResume

Description

The number of current fabric links is equal to or larger than the number of fabric links configured. (hwStackFabricPort=[hwStackFabricPort], hwFabricCurrentLinkNum=[hwFabricCurrentLinkNum], hwFabricConfiguredLinkNum=[hwFabricConfiguredLinkNum])

The number of available fabric port links is larger than or equal to the configured alarm threshold.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwFabricLinkLimitAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.31

Alarm ID

0x09da2003

Alarm Type

equipmentAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.30 hwFabricLinkLimitAlarm

Parameters

Name

Meaning

hwStackFabricPort

Indicates the fabric port number.

hwFabricCurrentLinkNum

Indicates the number of current links.

hwFabricConfiguredLinkNum

Indicates the configured alarm threshold.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.8

hwStackFabricPort

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.15

hwFabricCurrentLinkNum

N/A

1.3.6.1.4.1.2011.5.25.183.1.27.1.5

hwFabricConfiguredLinkNum

hwFabricPortIndex

Impact on the System

The downlink service port of the leaf switch connected to the fabric port restores to the normal state.

Possible Causes

Cause 1: The port and link recover from a fault.

Cause 2: The number of available links is increased or the alarm threshold is adjusted to be smaller than or equal to the number of current links.

Procedure
  1. This trap is informational only, and no action is required.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.35 hwFabricLinkProtocolAlarm

Description

The physical status of the fabric link for the logical port is up, but the protocol status is down. (hwStackFabricPort=[hwStackFabricPort])

The physical status of the fabric port link is Up, but the protocol status is Down.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwFabricLinkProtocolAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.35

Alarm ID

0x09a2201e

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.36 hwFabricLinkProtocolAlarmResume

Parameters

Name

Meaning

hwStackFabricPort

Indicates the fabric port number.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.8

hwStackFabricPort

N/A

Impact on the System

The fabric port link fails.

Possible Causes

Cause 1: The fabric port link fails.

Cause 2: Packet reception on the port times out.

Procedure
  • Cause 1: The fabric port link fails.
    1. Run the display alarm active command to check whether a link alarm is generated. If a link alarm is generated, check the connection or configuration according to the reason for the alarm.
    2. Run the display stack link-state last-down-reason command to check the reason why the fabric port link becomes Down and check the connection or configuration according to the reason.
    3. Collect alarm, log, and configuration information, and contact technical support personnel.
  • Cause 2: Packet reception on the port times out.
    1. Collect alarm, log, and configuration information, and contact technical support personnel.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.36 hwFabricLinkProtocolAlarmResume

Description

The physical status and protocol status of the fabric link for the logical port are up or down at the same time. (hwStackFabricPort=[hwStackFabricPort])

The physical status and protocol status of the fabric port link are both Up or Down.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwFabricLinkProtocolAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.36

Alarm ID

0x09a2201e

Alarm Type

equipmentAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.35 hwFabricLinkProtocolAlarm

Parameters

Name

Meaning

hwStackFabricPort

This object indicates the fabric port number.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.8

hwStackFabricPort

N/A

Impact on the System

The physical status of the fabric port link is Up, and the protocol status changes from Down to Up.

Possible Causes

The fabric port link recovers from a fault.

Procedure
  1. This trap is informational only, and no action is required.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.37 hwFabricMemberPortProtocolAlarm

Description

The physical status of the fabric link for the member port is up, but the protocol status is down. (hwStackFabricMemberPort=[hwStackFabricMemberPort])

The physical status of the fabric port link is Up, but the protocol status is Down.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwFabricMemberPortProtocolAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.37

Alarm ID

0x09a2201f

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.38 hwFabricMemberPortProtocolAlarmResume

Parameters

Name

Meaning

hwStackFabricMemberPort

This object indicates the member port number of the fabric port.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.9

hwStackFabricMemberPort

N/A

Impact on the System

The member port link of the fabric port fails.

Possible Causes

Receiving protocol packets times out on the port.

Procedure
  1. Collect alarm, log, and configuration information, and contact technical support personnel.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.38 hwFabricMemberPortProtocolAlarmResume

Description

The physical status and protocol status of the fabric link for the member port are up or down at the same time, or the fabric member port is deleted. (hwStackFabricMemberPort=[hwStackFabricMemberPort])

The physical status and protocol status of the member port link of the fabric port are both Up or Down, or the member port is deleted.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwFabricMemberPortProtocolAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.38

Alarm ID

0x09a2201f

Alarm Type

equipmentAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.37 hwFabricMemberPortProtocolAlarm

Parameters

Name

Meaning

hwStackFabricMemberPort

Indicates the member port number of the fabric port.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.9

hwStackFabricMemberPort

N/A

Impact on the System

The physical status of the member port link of the fabric port is Up, and the protocol status changes from Down to Up.

Possible Causes

The member port link of the fabric port recovers from a fault or the member port is deleted.

Procedure
  1. This trap is informational only, and no action is required.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.45 hwStackMemberPortSpeedDifferentAlarm

Description

The rates of member ports in a stack port are different. (hwStackPortName=[hwStackPortName])

The stack member ports have different rates.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackMemberPortSpeedDifferentAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.45

Alarm ID

0x09a22022

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.46 hwStackMemberPortSpeedDifferentAlarmResume

Parameters

Name

Meaning

hwStackPortName

Indicates the name of the stack port.

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.21.1.3

hwStackPortName

hwStackPortStackId

hwStackPortId

Impact on the System

Traffic may be interrupted on the stack port.

Possible Causes

Optical modules that mismatch the port rates are inserted into the stack member ports. For example, a 40GE optical module is inserted into a 100GE port.

Procedure
  1. Replace the optical modules that mismatch the port rates.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.46 hwStackMemberPortSpeedDifferentAlarmResume

Description

The rates of member ports in a stack port are same. (hwStackPortName=[hwStackPortName])

The stack member ports have the same rates.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackMemberPortSpeedDifferentAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.46

Alarm ID

0x09a22022

Alarm Type

equipmentAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.45 hwStackMemberPortSpeedDifferentAlarm

Parameters

Name

Meaning

hwStackPortName

Indicates the name of the stack port.

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.21.1.3

hwStackPortName

hwStackPortStackId

hwStackPortId

Impact on the System

None

Possible Causes

The stack member ports have the same rates.

Procedure
  1. This trap message is informational only, and no action is required.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.47 hwStackMemberPortProtocolAlarm

Description

The physical status of the stack member port is up, but the protocol status is down. (hwStackLocalIfName=[hwStackLocalIfName])

The physical status of the stack member port is Up, but its protocol status is Down.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackMemberPortProtocolAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.47

Alarm ID

0x09a22023

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.48 hwStackMemberPortProtocolAlarmResume

Parameters

Name

Meaning

hwStackLocalIfName

Indicates the name of the stack member port.

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.1

hwStackLocalIfName

N/A

Impact on the System

The link connecting to the stack member port is unavailable.

Possible Causes

The connection of the stack member port is incorrect or stack protocol packets are received or sent incorrectly.

Procedure
  1. Check whether the connection of the stack member port is correct. If not, correct it.
  2. Run the display interface interface-type interface-number command to check whether error packet statistics exist on the port. If so, check whether the optical modules of the two ends are properly inserted or have any fault.
  3. Run the display stack statistics command in the diagnostic view more than once to check whether the statistics about stack protocol packets sent or received are correct. If not, check the stack configuration or connections.
  4. Collect the trap, log, and configuration information, and then contact technical support personnel.

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.48 hwStackMemberPortProtocolAlarmResume

Description

The physical status and protocol status of the stack member port is up or down at the same time, or the stack member port is deleted. (hwStackLocalIfName=[hwStackLocalIfName])

The physical status and protocol status of the stack member port are both Up or Down, or the stack configuration is removed from the port.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackMemberPortProtocolAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.48

Alarm ID

0x09a22023

Alarm Type

communicationsAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.47 hwStackMemberPortProtocolAlarm

Parameters

Name

Meaning

hwStackLocalIfName

Indicates the name of the stack member port.

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.1

hwStackLocalIfName

N/A

Impact on the System

None

Possible Causes

The link fault of the stack member port is rectified, or the stack configuration is removed from the port.

Procedure
  1. This trap message is informational only, and no action is required.