Clearing NQA Test Statistics
Clearing NQA Test Statistics
Context
To obtain the latest test results, clear the current test
results by running the following commands.
Statistics cannot be restored after being cleared. Confirm the
action before you run the commands.
Statistics on the running test instance cannot be cleared.
Procedure
Run:
system-view
The system view is displayed.
Run:
nqatest-instanceadmin-nametest-name
The NQA view is displayed.
Run:
clear-records
The statistics about NQA test instances are cleared.