Removing the CX310
Scenarios
Remove the CX310 from the E9000 chassis. Before the operation, be familiar with the hardware devices.
To replace a switch module, see section "Replacing a Switch Module" in the E9000 Server V100R001 User Guide.
Impact on the System
After the switch module is removed, all services running on the switch module stop.
Prerequisites
Tools
- Protective gloves
- Electrostatic discharge (ESD) gloves
- Phillips screwdriver (PH2 is 6 mm or 0.24 in.)
Workflow
Procedure
- Determine the CX310 to be removed. Figure 3-10 shows the slot numbers.
- Determine the connection relationships between signal cables and ports on the CX310. Figure 3-11 shows the CX310 port types and numbers.
1
BMC serial port
2
SYS serial port
3
10GE optical port
-
-
- (Optional) Remove a serial cable.Figure 3-12 Removing a serial cable
The BMC serial port and SYS serial port are standard RJ45 ports and are disconnected in the same way.
- Remove an optical cable and optical module.
- Determine the optical module type and the optical port to be removed depending on site requirements.
- Remove the optical cable from the optical module. See (1) and (2) in Figure 3-13.
- Install the dust-proof cap for the optical cable. See (3) in Figure 3-13.
- Remove the optical module horizontally from the optical port, as shown in Figure 3-14.
If 10GE optical modules and cables have been removed and 40GE optical modules and cables do not need to be removed, go to 5.
- Remove the CX310.
- Use a Phillips screwdriver to loosen the two M3 captive screws. See (1) in Figure 3-15.
- Raise the two ejector levers on the CX310 completely and pull the switch module horizontally out of the chassis. See (2) and (3) in Figure 3-15.
- Lower the ejector levers on the CX310. See (4) in Figure 3-15.
An ESD bag holds only one switch module.
- Place the removed switch module into an ESD bag.
- Install a switch module filler panel.
- Raise the two ejector levers on the switch module filler panel and push the filler panel horizontally into the chassis as far as it will go. See (1) in Figure 3-16.
- Lower the two ejector levers on the switch module filler panel. See (2) in Figure 3-16.
- Use a Phillips screwdriver to tighten the two M3 captive screws on the switch module filler panel. See (3) in Figure 3-16.