CX311 Switch Module V100R001C00 User Guide 22

This document describes the CX311 10GE / FCoE converged switch module of the Tecal E9000 server in terms of its features, installation, removal, and configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Indicators

Indicators

By observing the indicators, you can determine the current operating status of the CX311.

Table 2-5 Indicators

Silkscreen

Meaning

Color

Description

STAT

Stacking status indicator

Green

  • Off: The CX311 is not powered on.
  • Blinking green for 10 times: The CX311 is being powered on.
  • Blinking green: The CX311 is in standby or slave state in a stack and is operating properly.
  • Steady green: The CX311 is in the active state in a stack or is not stacked, and is operating properly.

HLY

Health status indicator

Red and green

  • Off: The CX311 is not powered on.
  • Steady green: The CX311 is operating properly or has minor alarms.
  • Blinking red (1 Hz): A major alarm is generated.
  • Blinking red (4 Hz): A critical alarm is generated.
  • Blinking red (5 Hz): The CX311 is not securely installed.
NOTE:

It is difficult to identify the difference between blinking frequencies of 4 Hz and 5 Hz. If the indicator is blinking red quickly, you are advised to check whether the device has been installed properly and then check whether a critical alarm has been generated.

OFL

Offline button/indicator (reserved)

N/A

N/A

and

Connection status indicator for the 10GE optical port

Green

  • Off: The port is not properly connected.
  • Steady green: The port is properly connected.

and

Data transmission status indicator for the 10GE optical port

Orange

  • Off: No data is being transmitted over the port.
  • Blinking orange: Data is being sent or received over the port.

A

Data transmission status indicator for the 8G FC optical port

Orange

  • Off: No data is being transmitted over the port.
  • Blinking orange (twice/second): If the green indicator (L) is blinking twice per second at the same time, a high temperature alarm is generated.
  • Blinking orange (over two times/second): Data is being sent or received over the port.

L

Connection status indicator for the 8G FC optical port

Green

  • Off: No optical module is installed, or an exception occurs when the port is receiving optical signals.
  • Steady green: The link is properly connected.
  • Blinking green (once/second): The device is being registered or the port is in the diagnosis state.
  • Blinking green (twice/second): The port is not properly connected or the port is faulty. If the orange indicator (A) is blinking twice per second at the same time, a high temperature alarm is generated.