CX311 Switch Module V100R001C00 User Guide 22

This document describes the CX311 10GE / FCoE converged switch module of the Tecal E9000 server in terms of its features, installation, removal, and configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Internal Chassis Networking

Internal Chassis Networking

Figure 2-8 shows the internal chassis networking for the CX311 and compute nodes. Ports on compute nodes for connecting to the CX311 are provided by two mezzanine modules as follows:

  • Mezz 1 connects to the converged switching plane of the CX311s in slots 2X and 3X.
  • Mezz 2 connects to the converged switching plane of the CX311s in slots 1E and 4E.
Figure 2-8 Mapping between the CX311s and mezzanine modules on compute nodes

For details, see the E9000 Blade Server Mezzanine Module-Switch Module Interface Mapping Tool.

The following describes the mapping between the CX311s and mezzanine modules. For example, the CX311s are installed in slots 2X and 3X and connect to Mezz 1.

Port Mapping Between a Switch Module and a Mezzanine Module

Mapping between the CX311s and ports on the MZ311

The MZ311 provides four 10GE optical ports (ports 1 to 4). Ports 1 and 3 map to the converged switching plane of the CX311 in slot 2X. Ports 2 and 4 map to the converged switching plane of the CX311 in slot 3X.

Figure 2-9 Mapping between the CX311s and ports on the MZ311

Mapping between the CX311s and ports on the MZ510

The MZ510 provides two 10GE ports (ports 1 and 2). Ports 1 and 2 map to the converged switching plane of the CX311s in slots 2X and 3X respectively.

Figure 2-10 Mapping between the CX311s and ports on the MZ510

Mapping between the CX311s and ports on the MZ512

The MZ512 provides four 10GE optical ports (ports 1 to 4). Ports 1 and 3 map to the converged switching plane of the CX311 in slot 2X. Ports 2 and 4 map to the converged switching plane of the CX311 in slot 3X.

Figure 2-11 Mapping between the CX311s and ports on the MZ512