CX311 Switch Module V100R001C00 User Guide 22

This document describes the CX311 10GE / FCoE converged switch module of the Tecal E9000 server in terms of its features, installation, removal, and configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing the CX311

Installing the CX311

Prerequisites

Tools

  • Protective gloves
  • Electrostatic discharge (ESD) gloves
  • Phillips screwdriver (PH3 is 8 mm or 0.31 in.)

Workflow

Figure 3-1 Installation process

Procedure

  1. Install the chassis.
  2. Determine the position for installing the CX311 in the chassis.

    Figure 3-2 Slot numbers

  3. Remove the switch module filler panel.

    1. Use a Phillips screwdriver to loosen the two M3 captive screws on the switch module filler panel. See (1) in Figure 3-3.
      Figure 3-3 Removing the switch module filler panel
    2. Raise the two ejector levers on the switch module filler panel completely, and pull the filler panel horizontally out of the chassis. See (2) and (3) in Figure 3-3.
    3. Store the switch module filler panel for future use.

  4. Install the CX311.

    1. Raise the two ejector levers on the CX311 completely and push the CX311 horizontally into the chassis as far as it will go. See (1) and (2) in Figure 3-4.
      Figure 3-4 Installing the CX311
    2. Lower the two ejector levers on the CX311 until the CX311 is completely inserted. See (3) in Figure 3-4.
    3. Use a Phillips screwdriver to tighten the two M3 captive screws on the CX311. See (4) in Figure 3-4.

  5. Determine the connection relationships between signal cables and ports.

    Figure 3-5 Port types and numbers

    1

    BMC serial port

    2

    SYS serial port

    3

    10GE optical port

    4

    8G FC optical port

  6. (Optional) Connect a serial cable.

    Figure 3-6 Connecting a serial cable
    NOTE:

    The BMC serial port and SYS serial port are standard RJ45 ports and are connected in the same way.

  7. Connect an optical module and cable.

    1. Determine the optical module type and the optical port to be connected depending on site requirements.
    2. Insert the optical module into the optical port until the optical module is locked.
      Figure 3-7 Installing an optical module
    3. Remove the dust-proof caps from the optical cable. See (1) in Figure 3-8.
      Figure 3-8 Connecting an optical cable
    4. Insert the optical cable into the optical module. See (2) in Figure 3-8.
      NOTE:

      The methods for connecting an optical cable to a 10GE optical port and an 8G FC optical port are the same.

  8. Check the indicator status after the CX311 is powered on. For details, see Table 2-5.
  9. Configure the CX311. For details, see Configuring the CX311.