CX311 Switch Module V100R001C00 User Guide 22

This document describes the CX311 10GE / FCoE converged switch module of the Tecal E9000 server in terms of its features, installation, removal, and configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking the Switching Plane

Checking the Switching Plane

Check the converged switching plane operating status of the CX311 and ensure that the converged switching plane meets the basic requirements of data configuration.

Procedure

  1. Log in to the converged switching plane CLI.
  2. Run the following command on the converged switching plane CLI to check the current version of the converged switching plane:

    <HUAWEI> display version

    The command output is as follows:

    Huawei Versatile Routing Platform Software                
    VRP (R) software, Version 8.50 (OSCA V100R001C03)         
    Copyright (C) 2012-2013 Huawei Technologies Co., Ltd.     
    HUAWEI OSCA uptime is 0 day, 0 hours, 1 minutes         
                                                              
    CX311(Master) 1 : uptime is  0 day, 0 hours, 1 minutes  
            StartupTime 2013/05/16 17:43:57                 
    Memory    Size    : 2048 M bytes 
    FLASH     Size    : 1024 M bytes 
    CX311 version information          
    1. PCB      Version : CX311 VER B    
    2. MAB      Version : 0              
    3. Board    Type    : CX311          
    4. CPLD1    Version : 001            
    5. BIOS     Version : 2.42            
    6. Software Version : 1.01

    Software Version indicates the current software version.

  3. Check whether the software version is consistent with the planned one.

    • If yes, go to 4.
    • If no, contact Huawei technical support.

  4. Query the alarms of the converged switching plane.

    <HUAWEI> display alarm active

    The command output is as follows:

    1:Critical  2:Major  3: Minor  4:Warning 
    ------------------------------------------------------------------ 
    Sequence AlarmId    Level Date Time  Description                 
    ------------------------------------------------------------------     

    The parameters are described as follows:

    • Critical: critical alarm
    • Major: major alarm
    • Minor: minor alarm
    • Warning: warning alarm
    • Sequence: alarm sequence
    • AlarmId: alarm ID
    • Level: alarm severity
    • Date Time: date and time at which an alarm is generated
    • Description: alarm description

    If no information is displayed, no alarm is generated.

  5. Check whether an alarm is generated.

    • If yes, go to 6.
    • If no, no further action is required.

  6. Handle the alarm. For details, see the E9000 Server V100R001 Alarm Handling.