CX311 Switch Module V100R001C00 User Guide 22

This document describes the CX311 10GE / FCoE converged switch module of the Tecal E9000 server in terms of its features, installation, removal, and configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Changing the VLAN ID and Domain ID

Changing the VLAN ID and Domain ID

Scenarios

When switch modules are stacked, change the default virtual local area network (VLAN) ID (1002) and domain ID (1) for internal ports (connected to the converged switching plane) on the FCoE gateway in the standby switch module. The following assumes that the FCoE gateway works in Full Fabric mode. If the FCoE gateway works in Transparent mode, you only need to modify the VLAN ID.

In the network shown in Figure 4-5, the CX311s and converged switching planes are stacked but the FCoE gateways are not stacked. After the stacking system is complete, the FCoE gateway assigns a virtual Media Access Control (MAC) address to each host port for transmitting FCoE gateway packets based on the FCoE gateway domain ID and MAC addresses of the internal ports on the FCoE gateway. By default, the domain ID for FCoE gateways is 1, which leads to identical virtual MAC addresses. The converged switching planes are stacked, all FCoE gateway packets are forwarded in the same converged switching plane, and the default VLAN ID 1002 is used. These conditions may cause exceptions in data forwarding.

Figure 4-5 Networking

Prerequisites

Data

  • Domain ID of the FCoE gateway in the standby switch module, for example, 3.
  • VLAN ID for the internal ports on the FCoE gateway in the standby switch module, for example, 1003.

Procedure

  1. Log in to the FCoE gateway CLI.
  2. Change the domain ID.

    1. Enter the configuration mode.
      FCoE_GW: admin> admin start 
      FCoE_GW (admin): admin> config edit
    2. Change the domain ID.
      FCoE_GW (admin-config): admin>set config switch 
        A list of attributes with formatting and current values will follow. 
        Enter a new value or simply press the ENTER key to accept the current value. 
        If you wish to terminate this process before reaching the end of the list 
        press 'q' or 'Q' and the ENTER key to do so. 
       
        TransparentMode       (True / False)                         [False         ] 
          //Press Enter. 
        
        AdminState            (1=Online, 2=Offline, 3=Diagnostics) [Online        ] 
          //Press Enter. 
       
        BroadcastEnabled      (True / False)                         [True          ] 
          //Press Enter. 
       
        FdmiEnabled           (True / False)                         [True          ] 
          //Press Enter. 
       
        FdmiEntries           (decimal value, 0-1000)                [1000          ] 
          //Press Enter. 
       
        DefaultDomainID       (decimal value, 1-239)                 [1             ] 
        3  //Type a new domain ID, and press Enter. 
       
        DomainIDLock          (True / False)                         [False         ] 
          //Press Enter. 
       
        SymbolicName          (string, max=32 chars)                 [FCoE_GW       ] 
          //Press Enter. 
       
        PrincipalPriority     (decimal value, 1-255)                 [254           ] 
          //Press Enter. 
       
        ConfigDescription     (string, max=64 chars)                 [Default Config] 
          //Press Enter. 
       
       
        Finished configuring attributes. 
        This configuration must be saved (see config save command) and 
        activated (see config activate command) before it can take effect. 
        To discard this configuration use the config cancel command. 
       
      FCoE_GW (admin-config): admin>
    3. Save the configuration.
      FCoE_GW (admin-config): admin> config save 
       
        The config named default has been saved. 
       
      FCoE_GW (admin): admin> 
    4. Activate the configuration.

      The configuration takes effect immediately without a restart.

      FCoE_GW (admin): admin> config activate 
       
        The currently active configuration will be activated. 
        Please confirm (y/n): [n] y 
       
      FCoE_GW (admin): admin>

  3. Change the VLAN ID for the internal ports on the FCoE gateway.

    1. Configure zones.
      FCoE_GW: admin> admin start 
      FCoE_GW (admin): admin> config edit
    2. Create a VLAN ID.

      FCoE_GW (admin-config): admin> vlan VLAN ID create

      For example, set the VLAN ID for the internal ports on the FCoE gateway to 1003 by running the following command:

      FCoE_GW (admin-config): admin> vlan 1003 create
    3. Remove internal ports 12 to 19 (connected to the converged switching plane) on the FCoE gateway from VLAN 1002.
      FCoE_GW (admin-config): admin> vlan 1002 remove port 12 
      FCoE_GW (admin-config): admin> vlan 1002 remove port 13 
      FCoE_GW (admin-config): admin> vlan 1002 remove port 14 
      FCoE_GW (admin-config): admin> vlan 1002 remove port 15 
      FCoE_GW (admin-config): admin> vlan 1002 remove port 16 
      FCoE_GW (admin-config): admin> vlan 1002 remove port 17 
      FCoE_GW (admin-config): admin> vlan 1002 remove port 18 
      FCoE_GW (admin-config): admin> vlan 1002 remove port 19
    4. Configure a new VLAN for internal ports 12 to 19 on the FCoE gateway.

      FCoE_GW (admin-config): admin> vlan VLAN ID add port port number

      For example, create VLAN 1003 for internal ports 12 to 19 on the FCoE gateway by running the following commands:

      FCoE_GW (admin-config): admin> vlan 1003 add port 12 
      FCoE_GW (admin-config): admin> vlan 1003 add port 13 
      FCoE_GW (admin-config): admin> vlan 1003 add port 14 
      FCoE_GW (admin-config): admin> vlan 1003 add port 15 
      FCoE_GW (admin-config): admin> vlan 1003 add port 16 
      FCoE_GW (admin-config): admin> vlan 1003 add port 17 
      FCoE_GW (admin-config): admin> vlan 1003 add port 18 
      FCoE_GW (admin-config): admin> vlan 1003 add port 19
    5. Delete the default VLAN 1002 from the FCF module.
      FCoE_GW (admin-config): admin> fcf 0EFC00 remove vlan 1002
    6. Add a VLAN to the FCoE gateway.

      FCoE_GW (admin-config): admin> fcf 0EFC00 add vlan VLAN ID

      For example, set the VLAN ID for the internal ports on the FCoE gateway to 1003 by running the following command:

      FCoE_GW (admin-config): admin> fcf 0EFC00 add vlan 1003
    7. Save the configuration.
      FCoE_GW (admin-config): admin> config save 
       
        The config named default has been saved. 
       
      FCoE_GW (admin): admin> 
    8. Activate the configuration.

      The configuration takes effect immediately without a restart.

      FCoE_GW (admin): admin> config activate 
       
        The currently active configuration will be activated. 
        Please confirm (y/n): [n] y 
       
      FCoE_GW (admin): admin>
    9. Run the vlan list command to view port VLANs.
      FCoE_GW: admin> vlan list 
       
        Active VLAN Information 
      VLAN 1002 
        Ports                    None 
      VLAN 1003 
        Ports                    12-19
    10. Run the fcf list command to view the port FCF information, including VLAN information.
      FCoE_GW: admin> fcf list 
      Active FCF (FCoE Forwarder) Information  
      FCF 0EFC00  
      EnforceKeepAliveTimer True  
      KeepAliveTimer        8  
      FIPPriority           128  
      VLAN                  1003  
      NumMacs               None   

  4. Add all ports on the converged switching plane that are connected to the server to a VLAN.

    1. Log in to the converged switching plane CLI.

      For details, see Logging In to the CLI of Each Switching Plane.

    2. Add all ports that are connected to the server to a VLAN.

      [~CX311_C] interface port number

      [~CX311_C-port number] port hybrid tagged vlan VLAN ID

      For example, add port 10ge 3/1/1 to VLAN 1003 (for internal ports on the FCoE gateway) by running the following commands:

      [~CX311_C] interface 10ge 3/1/1 
      [~CX311_C-10ge 3/1/1] port hybrid tagged vlan 1003

  5. Add all internal ports on the converged switching plane that are connected to the FCoE gateway to a VLAN.

    Ports 10ge 3/20/1 to 10ge 3/20/8 on the converged switching plane are connected to the FCoE gateway. These ports are added to the VLAN for the internal ports on the FCoE gateway.

    For example, add port 10ge 3/20/1 to VLAN 1003 (VLAN for the internal ports on the FCoE gateway) by running the following commands: