CX311 Switch Module V100R001C00 User Guide 22

This document describes the CX311 10GE / FCoE converged switch module of the Tecal E9000 server in terms of its features, installation, removal, and configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Ports

Ports

The CX311 provides ports for users to operate and configure. The ports are used to send and receive data.

The CX311 Ethernet ports are numbered in Slot number/Subcard number/Port number format.

  • Slot number: indicates the slot number of the current switch module. Its value ranges from 1 to 4, from left to right mapping to slot numbers 1E, 2X, 3X, and 4E.
  • Subcard number: indicates the number of a subcard supported by switching service ports. The value ranges from 1 to 20.
  • Port number: indicates the sequence number of a port on a subcard.

For details about subcard numbers and port numbers, see Table 2-3 and Table 2-4.

For example, if the CX311 is in slot 2X, the first GE port on the upper right on the panel is numbered 10GE 2/17/16, as shown in Figure 2-5.

The numbers of the FC optical ports on the CX311 are Ext1:0 to Ext8:7, which map to ports 1 to 8 for FC optical ports on the panel, as shown in Figure 2-5.

Figure 2-5 Port naming rules

Table 2-3 describes the external ports on the CX311.

Table 2-3 External ports

Port

Type

Quantity

Subcard Number

Port Number

Description

Serial port

RJ45

2

-

-

The serial ports include the baseboard management controller (BMC) serial port and the SYS serial port. These ports comply with RS232, and do not have an indicator.

  • BMC serial port: Used to log in to the BMC command-line interface (CLI).
  • SYS serial port: Used to manage, maintain, and commission the converged switching plane and FCoE gateway.

    The SYS serial port connects to the converged switching plane by default. You can run systemcom to switch the plane on the BMC CLI.

The BMC serial port and the serial port of the converged switching plane support a baud rate of 115,200 bit/s.

The serial port of the FCoE gateway supports a baud rate of 9,600 bit/s.

10GE optical port (upper)

SFP+

16

17

The value ranges from 1 to 16.

The ports are numbered from 1 in ascending order from left to right and then from bottom to top.

The sixteen ports higher up on the panel are used to exchange data with an external network.

Two indicators are provided for each port. The orange indicator is the data transmission status indicator, and the green indicator is the connectivity status indicator.

8G FC optical port (lower)

SFP+

8

-

-

The eight ports lower down on the panel are used to connect to an FC storage network.

Two indicators are provided for each port. The orange indicator is the data transmission status indicator, and the green indicator is the connectivity status indicator.

Table 2-4 describes the internal ports on the CX311.

Table 2-4 Internal ports

Port

Quantity

Subcard Number

Port Number

Description

Example

10GE port

32

1–16

1 or 2

The ports connect to the front half-width slots 01 to 16, and map to subcard numbers from 1 to 16.

If the CX311 is in slot 2X, the ports connected to the compute node in slot 1 are 10GE 2/1/1 and 10GE 2/1/2.

40GE port

1

18

1

The port is used to connect switch modules in the 1E and 4E slots or in the 2X and 3X slots.

If the CX311 is in slot 2X, the port is numbered 40GE 2/18/1.

GE port

2

19

1 or 2

Two GE ports connect to two MM910s respectively. They are used to communicate with eth0 and eth2 in the MM910.

If the CX311 is in slot 2X, the ports are numbered GE 2/19/1 and GE 2/19/2.

10GE port

8

20

1 to 8

The ports connect to the MX510.

If the CX311 is in slot 2X, the ports are numbered 10GE 2/20/1 to 10GE 2/20/8.