No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CX311 Switch Module V100R001C00 User Guide 22

This document describes the CX311 10GE / FCoE converged switch module of the Tecal E9000 server in terms of its features, installation, removal, and configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting an IP Address for the Management Network Port

Setting an IP Address for the Management Network Port

Prerequisites

Data

Table 4-3 Required data

Name

Description

Example Value

IP address, subnet mask, and gateway of the converged switching plane management network port

You can log in to the converged switching plane CLI from a PC by using the IP address of the management network port.

  • IP address: 192.168.101.120
  • Subnet mask: 255.255.255.0
  • Gateway: 192.168.101.1
Table 4-4 Default data

Name

Default Data

Description

Initial user name and password of the MM910

  • User name: root
  • Password: Huawei12#$

The default user of the MM910 has all OS rights.

Software

PuTTY.exe: free software. PuTTY 0.60 or later is required for login over a serial port.

Procedure

  1. Log in to the BMC CLI.
  2. Log in to the HMM WebUI. For details, see Logging In to the HMM WebUI.
  3. Perform operations based on the MM910 versions.

    • If the MM910 version is (U54) 2.20 or earlier, go to 4.
    • If the MM910 version is later than (U54) 2.20, go to 8.

      You can run the smmget -l smm -d version command on the MM910 CLI to check the software version.

  4. In the navigation tree on HMM Web, choose System Management > Network Management.

    The Network Management page is displayed.

  5. Click the swiN tab.

    The IP Address page is displayed, as shown in Figure 4-2.

    • N indicates the slot number of the current switch module. Its value ranges from 1 to 4, mapping to slot numbers 1E, 2X, 3X, and 4E from left to right.
    • fabric indicates the converged switching plane.
    Figure 4-2 IP Address page

  6. Select a switching plane for which the IP address is to be configured, and enter the IP address and subnet mask.
  7. Click Modify, and complete the modification as prompted. Then click Query to check that the settings take effect.

    The IP address configuration is complete.

  8. On HMM Web, choose Chassis Settings.

    The Chassis Settings page is displayed.

  9. In the navigation tree on the left, choose Network Settings > Swi.
  10. Click Edit to edit the IP addresses of management network ports of the converged switching plane in specific slots.

    Fabric indicates the converged switching plane.

  11. Click Deliver.

    The IP addresses of converged switching plane management network ports are successfully set.

  12. (Optional) Configure the switching plane gateway.

    1. Connect to the MM910 floating IP address over SSH to log in to the MM910 CLI.

      PuTTY is used as an example for login over SSH. For details, see Logging In to the MM910 CLI over a Network Port by Using PuTTY.

    2. Configure a gateway address for the Ethernet switching plane so that the switching plane can properly communicate with the PC.

      smmset -l swiN:fruM -d route -v targetvalue maskvalue gatewayvalue

      The parameters are described as follows:

      • N: specifies the slot number of a switch module. Its value ranges from 1 to 4, mapping to switch module slots 1E, 2X, 3X, and 4E from left to right.
      • M: indicates the ID of a switching plane. The value of the converged switching plane is 2.
      • targetvalue: specifies the target network segment IP address of the switching plane.
      • maskvalue: specifies the subnet mask of the switching plane.
      • gatewayvalue: specifies the gateway IP address of the switching plane.