No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CX311 Switch Module V100R001C00 User Guide 22

This document describes the CX311 10GE / FCoE converged switch module of the Tecal E9000 server in terms of its features, installation, removal, and configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Technical Specifications

Technical Specifications

Table 2-7 Technical specifications

Category

Item

Specifications

Physical specifications

Dimensions (H x W x D)

388.55 mm x 35.06 mm x 272.15 mm (15.30 in. x 1.38 in. x 10.71 in.)

Color

Silver

Weight

3 kg (6.62 lb)

Environmental specifications

Temperature

  • Operating temperature: 5°C to 40°C (41°F to 104°F) (ASHRAE Class A3 compliant)
  • Storage temperature: –40°C to +65°C (–40°F to +149°F)
  • Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)
  • Temperature change rate: < 20°C/h (36°F/h)

Relative humidity

  • Operating humidity: 5% RH to 85% RH (non-condensing)
  • Storage humidity: 5% RH to 95% RH (non-condensing)
  • Long-term storage humidity: 30% RH to 69% RH (non-condensing)
  • Humidity change rate: < 20% RH/h

Altitude

At an altitude of 900 m (2952.72 ft), the highest operating temperature is 40°C (104°F).

When the device is used at an altitude of 900 m to 5000 m (2952.72 ft to 16,404 ft), the highest operating temperature decreases by 1°C (1.8°F) for every increase of 300 m (984.24 ft).

Corrosive air pollutant

  • Corrosion rate of the copper test piece: < 300 Å/month (in compliance with the ANSI/ISA-71.04-2013 gaseous corrosion level G1)
  • Corrosion rate of the silver test piece: < 200 Å/month

Particulate pollutant

  • The ISO14664-1 Class 8 requirements are met.

    It is recommended that a professional company monitor particulate pollutants in the equipment room.

  • There is no explosive, conductive, magnetic, or corrosive dust in the equipment room.

Input power supply

Rated input voltage

12 V DC

Power consumption

Maximum power consumption

172 W

Table 2-8 Network switching specifications

Attribute

Service Feature

Specifications

Device performance

Number of ports on the panel

  • One BMC serial port and one SYS serial port
  • Sixteen 10GE optical ports
  • Eight 8G FC optical ports

Port rate

10GE optical ports and GE optical ports are supported.

Service port stacking

Two 40GE ports on two switch modules can be stacked. (10GE ports and 40GE ports cannot be stacked into one logical interface.)

Switching capability (throughput)

1.28 Tbit/s

Packet forwarding rate

960 Mpps

Ethernet service

Number of Media Access Control (MAC) addresses

131,072

Number of VLANs

4063

NOTE:

A switch module reserves 31 internal virtual local area networks (VLANs). The default value ranges from 4064 to 4094. The reserved VLANs are in a consecutive range.

Number of Eth-Trunk interfaces

128 Eth-Trunk interfaces. Each Eth-Trunk interface supports a maximum of 16 member interfaces.

Number of Address Resolution Protocols (ARPs) for the device

16,384

Jumbo frame length (in byte)

9216

Quality of service (QoS)

Number of queues for a port

8

Number of Committed Access Rate (CAR)

  • Ingress: 2048
  • Egress: 1024

Packet cache

4 MB

ACL

ACLv4

  • Pre-Ingress: 750
  • Ingress: 1500
  • Egress: 1000

L3VPN

VPN routing and forwarding (VRF)

128

Multiprotocol Label Switching (MPLS) is not supported.

Number of virtual private network (VPN) routes

16,384

IP address unicast

Number of route entries

16,384

Number of IPV4 forwarding information bases (FIBs)

16,384

Multicast

Number of layer 2 multicast forwarding entries

8192

Reliability service

Bidirectional Forwarding Detection (BFD)

Virtual Router Redundancy Protocol (VRRP)

  • Number of VRRP backup groups: 64
  • Number of VRRP management groups: 64
  • Number of virtual IP addresses for each VRRP backup group: 16

Multiple Spanning Tree Protocol (MSTP)

Maximum number of instances in the device: 48

Enhanced Ethernet

Transparent Interconnection of Lots of Links (TRILL)

  • Number of network nodes: 512
  • Number of CE-VLANs: 4062
  • Load-sharing specifications: 16 links
Translation
Download
Updated: 2018-09-20

Document ID: EDOC1000018097

Views: 60496

Downloads: 3389

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next