CE6850-48S6Q-HI
Version Mapping
Table 2-130 lists the mappings between the CE6850-48S6Q-HI and software versions.
Appearance and Structure
The figures in this document are for reference only.
1 |
Ground screw |
2 |
Two ETH management ports (combo) Applicable transceiver modules for the GE optical port of the combo port:
NOTE:
The combo optical port uses a 100M or GE optical module and matching fibers. A 100M optical module can be used only after the switch starts successfully. |
3 |
Console port |
4 |
USB port |
5 |
Mini USB port |
6 |
Barcode label
NOTE:
This label is drawable, and you can pull it outward to view the ESN barcode and MAC address of the switch. |
7 |
Fan slot 1 Applicable fan modules:
|
8 |
Fan slot 2 Applicable fan modules:
|
9 |
Power supply slot 1 |
10 |
Power supply slot 2 |
11 |
Forty-eight 10GE SFP+ Ethernet optical ports Applicable transceiver modules and cables:
|
12 |
Six 40GE QSFP+ Ethernet optical ports NOTE:
A 40GE QSFP+ port can be split into four 10GE ports. |
13 |
Three port-side mounting holes for mounting brackets |
14 |
Four middle mounting holes for mounting brackets |
15 |
Four power-supply-side mounting holes for mounting brackets |
- |
- |
Slot
Power supply slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) have two power supply slots, in which power modules can be installed to provide power to the chassis. A chassis can have one or two power modules. Double power modules can provide higher reliability.
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI) support double power modules (1+1 backup).- When both power modules are working properly, they equally provide power for a chassis.
- When one power module fails, the other one provides all power required for a chassis.
Fan slot
The CloudEngine 8800, 7800, 6800, and 5800 series switches (except the CE8850-64CQ-EI, CE6863-48S6CQ, CE6881-48S6CQ, CE6820-48S6CQ, CE6863-48S6CQ-K, CE6881-48S6CQ-K, CE6881E-48S6CQ and CE6857-48S6CQ-EI) have two fan slots, in which fan modules can be installed to cool the chassis, ensuring efficient heat dissipation and system stability. A chassis must have two working fan modules to ensure normal operating.
All fan modules are hot swappable.
Airflow
- Front-to-back airflow: The power modules and fan modules using front-to-back airflow are marked
or
. Air flows into the chassis from the power supply side and flows out from the port side, as shown in Figure 2-60 (CE5800 as an example).
- Back-to-front airflow: The power modules and fan modules using back-to-front airflow are marked
or
. Air flows into the chassis from the port side and flows out from the power supply side, as shown in Figure 2-61 (CE5800 as an example).
When the power module and fan module use forcible heat dissipation, they must use the same airflow method. For example, if the power module with back-to-front airflow is used, the fan module with back-to-front airflow must be used.
Indicators
No. |
Indicator |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
SYS |
System status indicator |
Green |
Off |
The system is not running. |
Fast blinking |
The system is starting. |
||||
Slow blinking |
The system is running normally. |
||||
Red |
Steady on |
|
|||
2 |
MST |
Stack master/slave indicator NOTE:
In V200R003C00 and later versions, you can use the dfs-master led enable command to enable the stack master/slave indicator to display the DFS group master and backup status. After the stack master/slave indicator is enabled to display the DFS group master and backup status, the stack master/slave indicator on the DFS master device is steady on and that on the DFS backup device is off. |
Green |
Off |
The switch is not a stack master. |
Steady on |
The switch is a stack master or standalone switch. |
||||
3 |
ID |
ID indicator |
Blue |
Off |
The ID indicator is not used (default state). |
Steady on |
The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain. |
||||
4 |
- |
Service port indicator (10GE optical port) NOTE:
Each 10GE optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green). Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top. |
Green |
Off |
The port is not connected or has been shut down. |
Steady on |
A link is established on the port. |
||||
Yellow |
Off |
The port is not sending or receiving data. |
|||
Blinking |
The port is sending or receiving data. |
||||
5 |
- |
Service port indicator (40GE optical port) NOTE:
Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top. |
Green |
Off |
The port is not connected or has been shut down. |
Steady on |
A link is established on the port. |
||||
Blinking |
The port is sending or receiving data. |
||||
When a 40GE port is configured as four 10GE ports, this indicator shows the status of a 10GE port. The sequence number of the indicated 10GE port is identified by indicators 40GE Breakout 1/2/3/4 on the lower right corner of the panel. NOTE:
Each 40GE port has a single-color indicator, which shows the status of the 40GE port by default. If a 40GE port is not split and is connected to four 10GE ports on a remote device using a one-to-four high-speed cable, the 40GE port cannot go Up and its indicator is off. |
|||||
6 |
- |
40GE Breakout 1/2/3/4 (sequence number indicators of 10GE ports converted from a 40GE port) NOTE:
Indicators 1, 2, 3, 4 turn on in cyclic order, with each indicator keeping on for 5s. |
Green |
Off |
40GE ports are not split into four 10GE ports. |
Steady on |
At least one 40GE port has been split into four 10GE ports. When one or more 40GE ports are configured as four 10GE ports, these indicators identify the sequence numbers of the 10GE ports. A port indicator (5 in Figure 2-62) shows the status of a 10GE port converted from the corresponding 40GE port:
The following is an example: The first 40GE port shown in Figure 2-62 is split into four 10GE ports, and the second 40GE port is not split.
|
||||
7 |
USB |
USB-based deployment indicator |
Green |
Off |
USB-based deployment is disabled (default state). |
Steady on |
USB-based deployment has been completed. |
||||
Blinking |
The system is reading data from a USB flash drive. |
||||
Red |
Steady on |
USB-based deployment has failed. |
|||
8 |
ACT |
Mini USB port indicator |
Green |
Off |
The Mini USB port is inactive, and the console port can be used. |
Steady on |
The Mini USB port is active, and the console port cannot be used. |
||||
9 |
- |
ETH management port indicator |
Green |
Off |
No link is established on the port. |
Steady on |
A link is established on the port. |
||||
Yellow |
Blinking |
The port is sending or receiving data. |
Ports
10GE SFP+ Ethernet Optical Port
40GE QSFP+ Ethernet Optical Port
Console Port
- The console port and Mini USB port share one internal serial port. You can use the console port or Mini USB port as the serial port according to your needs. When the Mini USB is activated, the console port cannot be used.
- When both the console port and Mini-USB port have a cable connected, the Mini-USB port is used.
Mini USB Port
The Mini USB port can connect to a configuration terminal for onsite configuration of the system, but the configuration terminal must have a USB serial port driver installed. The Mini USB port is used as the serial port once a link is established on the port.
ETH Management Port (Combo)
The combo port automatically selects the working mode as follows:
- If the optical port has no optical module installed and the electrical port has no network cable connected, the port type depends on which port is connected first. If the electrical port is connected by a network cable first, the electrical port is used for data switching. If the optical port has an optical module installed first, the optical port is used for data switching.
- If the electrical port has a network cable connected and is in Up state, the electrical port is still used for data switching when the optical port has an optical module installed.
- If the optical port has an optical module installed and is in Up state, the optical port is still used for data switching when the electrical port has a network cable connected.
- If the optical port has an optical module and optical fiber installed and the electrical port has a network cable connected, the optical port is used for data switching after the switch restarts.
Attribute |
Description |
---|---|
Connector type |
RJ45 |
Standards compliance |
IEEE802.3ab |
Working mode |
Supported rate: 10/100/1000 Mbit/s auto-sensing Full-duplex |
Maximum transmission distance |
100 m |
The CE6850-48S6Q-HI switches have two ETH management ports (combo). Pay attention to the following when using the two management ports:
- The two ports cannot be used together, and you must choose one of them to use.
- Before start of a CE6850-48S6Q-HI, you can select interface 1 or interface 2 in the BIOS menu. Interface 1 is the default choice. For details, see "Modify parameters" in the Basic Configuration Guide - BIOS Menu.
- After registration of the switch succeeds:
- If both the management ports have a cable connected and are in Up state, port 1 acts as the primary management port and port 2 becomes the backup automatically. The management interface number displayed on the command line interface is MEth0/0/0, regardless of which port is used.
- If cables are connected to the two ETH management ports after successful registration of the switch, the port that is connected first is used as the primary management port.
- If port 1 fails, the system switches management traffic to port 2 automatically. When port 1 recovers, management traffic cannot be switched back to port 1, unless port 2 fails or the switch restarts. You can observe indicators on the ETH management ports to determine which port is used currently. (The Link indicator of the ETH management port used is steady green. If data is being transmitted on this port, its ACT indicator is blinking yellow. The indicators of the backup port are off.)
USB Port
A USB flash drive can be connected to the USB port for log backup, system software backup and uploading, or USB-based deployment.
Specifications
Item |
Description |
|
---|---|---|
Physical specifications |
|
|
Environment parameters |
Temperature |
|
Relative humidity |
5% RH to 95% RH, noncondensing |
|
Altitude |
< 5000 m (16404 ft.) |
|
Noise (sound pressure, 27°C) |
|
|
Power specifications |
Power source type |
AC/DC/high-voltage DC |
AC power input |
|
|
DC power input |
|
|
High-voltage DC power input |
|
|
Rated input current |
|
|
Chassis power consumption |
Maximum power consumption |
272 W |
Typical power consumption |
166 W (100% throughput, SFP+ cables on 48 ports and QSFP+ cables on 6 ports, double power modules) |
|
Chassis heat dissipation |
Maximum heat dissipation |
928 BTU/hr |
Typical heat dissipation |
566 BTU/hr (100% throughput, SFP+ cables on 48 ports and QSFP+ cables on 6 ports, double power modules) |
|
Surge protection |
Power module:
|
|
Heat dissipation |
Heat dissipation mode |
Air cooling |
Airflow |
Front-to-back or back-to-front, depending on the fan modules and power modules |
|
Reliability and availability |
Power module backup |
1+1 backup |
Fan module backup |
Not supported |
|
Hot swap |
Supported by all power modules and fan modules |
|
Mean time between failures (MTBF) |
56.21 years |
|
Mean time to repair (MTTR) |
1.7 hours |
|
Availability |
0.9999965570 |
|
Technical specifications |
Processor |
1.5 GHz, quad-core |
DRAM Memory |
4 GB |
|
NOR Flash |
16 MB |
|
NAND Flash |
1 GB |
|
Stack |
Service port supporting the stack function |
10GE optical ports and 40GE optical ports |
Certification |
|
Ordering Information
Ordering information is subject to change without notice in the case of product upgrades. Ordering information provided in this manual is for reference only. To obtain latest ordering information, contact Huawei switch distributors or local Huawei representative office.
Table 2-138 provides the ordering information.
Part Number |
Part Model |
Part Description |
---|---|---|
02359314 |
CE6850-HI-B00 |
CE6850-48S6Q-HI Switch (2*600W AC Power Module, 2*FAN Box, Port-side Exhaust) |
02350EHE |
CE6850-HI-B-B0A |
CE6850-48S6Q-HI Switch (2*600W AC Power Module, 2*FAN Box, Port-side Intake) |
02350EHC |
CE6850-48S6Q-HI-F |
CE6850-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, 2*FAN Box, Port-side Exhaust, Without Power Module) |
02350EHD |
CE6850-48S6Q-HI-B |
CE6850-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, 2*FAN Box, Port-side Intake, Without Power Module) |
02359313 |
CE6850-48S6Q-HI |
CE6850-48S6Q-HI Switch (48-Port 10G SFP+, 6-Port 40GE QSFP+, Without FAN Box and Power Module) |