1200 W High-voltage DC Power Module (PHD-1K2WA)
Version Mapping
1200 W high-voltage DC power modules are classified into two types depending on the airflow designs: PHD-1K2WA-B (back-to-front airflow, air exhaust on power module panel) and PHD-1K2WA-F (F: front-to-back airflow, air intake on power module panel).
Table 3-61 describes the mapping between switch models and 1200 W high-voltage DC power modules.
Switch Model |
PHD-1K2WA-B |
PHD-1K2WA-F |
---|---|---|
CE8860-4C-EI |
Supported in V100R006C00 and later versions |
Supported in V100R006C00 and later versions |
CE8850-64CQ-EI |
Supported in V200R005C00 and later versions |
Supported in V200R005C00 and later versions |
CE6850-48S6Q-HI CE6850U-48S6Q-HI CE6850-48T6Q-HI CE6850U-24S2Q-HI CE6855-48T6Q-HI CE6856-48T6Q-HI CE6875-48S4CQ-EI |
Supported in V200R005C00 and later versions |
Supported in V200R005C00 and later versions |
CE8861-4C-EI CE8868-4C-EI |
Supported in V200R005C10 and later versions |
Supported in V200R005C10 and later versions |
Other models |
Not supported |
Not supported |
Appearance
Figure 3-53 shows the appearance of a PHD-1K2WA-B power module, and Figure 3-54 shows the appearance of a PHD-1K2WA-F power module.
Function
PHD-1K2WA-B and PHD-1K2WA-F use different airflow designs but have the same functions. Table 3-62 describes the functions of them.
Function |
Description |
|
---|---|---|
Input protection |
Input overvoltage protection and undervoltage protection |
In either of the two protection states, the power module stops supplying power. When the input voltage restores to the normal range, the power module automatically resumes power supply. |
Input overcurrent protection |
In this protection state, the power module stops supplying power and cannot automatically resume power supply when the input current restores to the normal range. |
|
Output protection |
Output overvoltage protection |
In this protection state, the power adapter stops supplying power intermittently. When the output voltage restores to the normal range, the power adapter automatically resumes power supply. |
Output overcurrent protection |
In this protection state, the power module supplies power intermittently. When the output current is limited within a range, the power module automatically resumes power supply. |
|
Output short-circuit protection |
In this protection state, the power module supplies power intermittently. When the short circuit is removed, the power module automatically resumes power supply. |
|
Overtemperature protection |
When the temperature of the power module exceeds a specified threshold, the power module stops supplying power. When the temperature falls into the normal range, the power module automatically resumes power supply. |
|
Heat dissipation |
|
|
Hot swap |
Supported |
When a power module enters overtemperature protection state, take measures to lower its temperature. The power module can automatically resume power supply when the temperature falls within the normal range.
Panel
Figure 3-55 and Figure 3-56 show the panels of 1200 W high-voltage DC power modules.
1. Lock |
2. Indicator |
3. Fan air vent |
4. Handle NOTE:
Each 1200 W high-voltage power module is delivered with a velcro strap on the handle. This velcro strap is used to bundle the power cable to the handle. |
5. Airflow flag
|
6. Power socket |
- |
- |
Table 3-63 describes the indicator on a 1200 W high-voltage DC power module.
Indicator |
Color |
Status |
Description |
---|---|---|---|
STAT: running status indicator |
Green |
Off |
The power module receives no power input. |
Steady on |
The power module is working normally. |
||
Blinking |
The power module is in loading or standby state, or the power cable has been connected but the power module is not installed in the switch. |
||
Red |
Steady on |
|
Specifications
Table 3-64 lists technical specifications of 1200 W high-voltage DC power modules.
Item |
PHD-1K2WA-B |
PHD-1K2WA-F |
---|---|---|
Dimensions (W x D x H) |
66.0 mm x 340.0 mm x 39.6 mm (2.6 in. x 13.4 in. x 1.6 in.) |
|
Weight |
1.5 kg (3.31 lb) |
|
Rated voltage range of 380 V high-voltage DC power input: |
240-380 V DC |
|
Maximum voltage range of 380 V high-voltage DC power input: |
188-400 V DC |
|
Rated input current |
8 A |
|
Rated output current |
100 A |
|
Rated output voltage |
12 V |
|
Rated output power |
1200 W |
|
Part number |
02311GLP |
02311GLN |