1200 W High-Voltage DC Power Module (PHD1K2S12-DB)
Version Mapping
Only the PHD1K2S12-DB (B: back-to-front airflow, air exhaust on power module panel) 1200 W high-voltage DC power module is available.
Table 3-57 describes the mapping between switch models and the 1200 W high-voltage DC power module.
Appearance
Figure 3-53 shows the appearance of the PHD1K2S12-DB power module.
Function
Table 3-58 describes the functions of the PHD1K2S12-DB power module.
Function |
Description |
|
---|---|---|
Input protection |
Input overvoltage protection and undervoltage protection |
In either of the two protection states, the power module stops supplying power. When the input voltage restores to the normal range, the power module automatically resumes power supply. |
Input overcurrent protection |
In this protection state, the power module stops supplying power and cannot automatically resume power supply when the input current restores to the normal range. |
|
Output protection |
Output overvoltage protection |
In this protection state, the power module stops supplying power intermittently. When the system recovers from output overvoltage, the power module automatically resumes power supply. |
Output overcurrent protection |
In this protection state, the power module supplies power intermittently. When the output current is limited within a range, the power module automatically resumes power supply. |
|
Output short-circuit protection |
In this protection state, the power module supplies power intermittently. When the short circuit is removed, the power module automatically resumes power supply. |
|
Overtemperature protection |
When the temperature of the power module exceeds a specified threshold, the power module stops supplying power. When the temperature falls into the normal range, the power module automatically resumes power supply. |
|
Heat dissipation |
PHD1K2S12-DB: back-to-front airflow |
|
Hot swap |
Supported |
When a power module enters overtemperature protection state, take measures to lower its temperature. The power module can automatically resume power supply when the temperature falls within the normal range.
Panel
Figure 3-54 shows the panel of the PHD1K2S12-DB power module.
1. Lock |
2. Indicator |
3. Fan air vent |
4. Handle NOTE:
Each power module is delivered with a velcro strap on the handle. This velcro strap is used to bundle the power cable to the handle. |
5. Airflow flag
|
6. Power socket |
- |
- |
Table 3-59 describes the indicator on the panel of the 1200 W high-voltage DC power module.
Indicator |
Color |
Status |
Description |
---|---|---|---|
STAT: running status indicator |
Green |
Steady off |
The power input is abnormal (for example, no input, overvoltage, or undervoltage), or the power module is in overtemperature protection state. |
Steady on |
The power module is working properly. |
||
Blinking |
The system software of the switch is being upgraded or downgraded, or the power output is abnormal (for example, overcurrent, short circuit, or overvoltage). |
Specifications
Table 3-60 lists technical specifications of 1200 W high-voltage DC power modules.
Item |
PHD1K2S12-DB |
---|---|
Dimensions (H x W x D) |
39.6 mm x 90.0 mm x 215.0 mm (1.56 in. x 3.54 in. x 8.46 in.) |
Weight |
1.5 kg (3.31 lb) |
Rated voltage range of 380 V high-voltage DC power input |
240-380 V DC |
Maximum voltage range of 380 V high-voltage DC power input |
190 V DC to 400 V DC |
Rated input current |
8 A |
Rated output current |
100 A |
Rated output voltage |
12 V |
Rated output power |
1200 W |
Environment specifications |
|
Part number |
02270183 |