No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CX910 Switch Module V100R001C10 User Guide 15

This document describes the CX910 10GE switch module (CX910 for short) of the Tecal E9000 server in terms of its features, installation, removal, and configuration. This document applies to the CX910 whose 10GE switching planes use the software versions of 1.2.1.0.39, 2.00 and later.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Internal Chassis Networking

Internal Chassis Networking

This topic describes connection relationships between the CX910 and mezz modules on compute nodes.

For details, see E9000 Blade Server Mezz Module-Switch Module Interface Mapping Tool.

Figure 2-8 shows the internal chassis networking for the CX910 and compute nodes. Ports on compute nodes for connecting to the CX910 are provided by two mezz modules. The mapping between the CX910 and the NIC and mezz modules is described as follows:

  • Mezz 1 connects to 10GE switching planes of the CX910s in slots 2X and 3X.
  • Mezz 2 connects to 10GE switching planes of the CX910s in slots 1E and 4E.
Figure 2-8 Mapping between the CX910 and mezz modules on compute nodes

Mapping Between the CX910 and Ports on Mezz Modules

Mapping between the CX910 and ports on the MZ311

The MZ311 provides four 10GE optical ports, including ports 1, 2, 3, and 4. Ports 1 and 3 map to the 10GE switching plane of the CX910 in slot 2X, and ports 2 and 4 map to the 10GE switching plane of the CX910 in slot 3X.

Figure 2-9 Mapping between the CX910 and ports on the MZ311

Mapping between the CX910 and ports on the MZ510

The two 10GE optical ports (ports 1 and 2) on the MZ510 map to the 10GE switching planes of the CX910s in slots 2X and 3X respectively.

Figure 2-10 Mapping between the CX910 and ports on the MZ510

Mapping between the CX910 and ports on the MZ512

The MZ512 provides four 10GE optical ports, including ports 1, 2, 3, and 4. Ports 1 and 3 map to the 10GE switching plane of the CX910 in slot 2X, and ports 2 and 4 map to the 10GE switching plane of the CX910 in slot 3X.

Figure 2-11 Mapping between the CX910 and ports on the MZ512
Translation
Download
Updated: 2018-09-20

Document ID: EDOC1000036339

Views: 12853

Downloads: 238

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next