CX913 Switch Module V100R001C10 User Guide 15

This document describes the CX913 10GE switch module (CX913 for short) of the Tecal E9000 server in terms of its features, installation, removal, and configuration. This document applies to the CX913 whose 10GE switching planes use the software versions of 1.2.1.0.39, 2.00 and later.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Internal Chassis Networking

Internal Chassis Networking

This topic describes connection relationships between the CX913 and mezz modules on compute nodes.

For details, see E9000 Blade Server Mezz Module-Switch Module Interface Mapping Tool.

Figure 2-8 shows the internal chassis networking for the CX913 and compute nodes. Ports on compute nodes for connecting to the CX913 are provided by two mezz modules. The mapping between the CX913 and the NIC and mezz modules is described as follows:

  • Mezz 1 connects to the 10GE switching planes and FC pass through planes of the CX913s in slots 2X and 3X.
  • Mezz 2 connects to the 10GE switching planes and FC pass through planes of the CX913s in slots 1E and 4E.
Figure 2-8 Mapping between the CX913 and mezz modules on compute nodes

Mapping Between the CX913 and Ports on Mezz Modules

Mapping between the CX913 and ports on the MZ311

The MZ311 provides four 10GE optical ports, including ports 1, 2, 3, and 4. Ports 1 and 3 map to the 10GE switching plane of the CX913 in slot 2X, and ports 2 and 4 map to the 10GE switching plane of the CX913 in slot 3X.

Figure 2-9 Mapping between the CX913 and ports on the MZ311

Mapping between the CX913 and ports on the MZ510

The two 10GE optical ports (ports 1 and 2) on the MZ510 map to the 10GE switching planes of the CX913s in slots 2X and 3X respectively.

Figure 2-10 Mapping between the CX913 and ports on the MZ510

Mapping between the CX913 and ports on the MZ512

The MZ512 provides four 10GE optical ports, including ports 1, 2, 3, and 4. Ports 1 and 3 map to the 10GE switching plane of the CX913 in slot 2X, and ports 2 and 4 map to the 10GE switching plane of the CX913 in slot 3X.

Figure 2-11 Mapping between the CX913 and ports on the MZ512

Mapping between the CX913 and ports on the MZ910

The two 10GE ports (ports 1 and 2) on the MZ910 map to the 10GE switching planes of the CX913s in slots 3X and 2X respectivel.

The two 8G FC ports (ports 3 and 4) on the MZ910 map to the FC pass through planes of the CX913s in slots 3X and 2X respectively.

Figure 2-12 Mapping between the CX913 and ports on the MZ910