Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
The Indicator of a Fan Module Is Steady Red or Blinking

The Indicator of a Fan Module Is Steady Red or Blinking

Fault Description

The indicator of a fan module is steady red or blinking.

Possible Causes

  • The fan module is not properly installed in the fan slot.
  • Fan blades are blocked or stop rotating because of heavy dust.
  • The fan module is faulty.

Troubleshooting Procedure

  1. Check whether the fan module is securely installed. If not, remove and reinstall the fan module (hot swappable).
  2. Remove the fan module and check whether fan blades are blocked or covered with heavy dust.
    • If fan blades are blocked by an obstacle, remove the obstacle.
    • If fan blades have heavy dust, use a brush to clean fan blades.
  3. Install another fan module of the same model into the fan slot. If the new fan module can work normally, the original fan module has failed.