Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Replacing the Mold of the Crimping Tool

Replacing the Mold of the Crimping Tool

Procedure

  1. Hold the handles of a pair of COAX crimping tools. Loosen the two fastening screws counterclockwise, as shown in Figure 7-72.

    Figure 7-72  Loosening two fastening screws

  2. Hold the handles of the COAX crimping tools to open the self-locking mechanism. The jaw of the COAX crimping tools opens automatically, as shown in Figure 7-73.

    Figure 7-73  Pliers jaw opening automatically

  3. Remove the mold from the COAX crimping tools, as shown in Figure 7-74.

    Figure 7-74  Removing the mold from the COAX crimping tools

  4. Place the mold to be installed into the jaw of the COAX crimping tools and align the screw holes, as shown in Figure 7-75.

    Figure 7-75  Installing a new mold in the COAX crimping tool

    Keep the short side of the mold inwards and the long side outwards, with the teeth of the mold aligning from the larger size to the smaller size.

  5. Hold the handles of the COAX crimping tools tightly to match the mold and the jaw completely. Align the screw holes, as shown in Figure 7-76.

    Figure 7-76  Aligning the screw holes

  6. Hold the handles of the COAX crimping tools with one hand. Tighten the two fastening screws clockwise. Figure 7-77 and Figure 7-78shows the mold installed in the COAX crimping tool.

    Figure 7-77  Mold installed in the COAX crimping tool

    Figure 7-78  An installed mold