Huawei Server Brickland Platform BIOS Parameter Reference 23

This document describes the basic input/output system (BIOS) menu structure, parameters and common tasks based on the Brickland platform.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling or Disabling CMCI

Enabling or Disabling CMCI

This topic describes how to enable or disable the Corrected Machine Check Interrupt (CMCI) function.

Scenarios

Enable or disable the CMCI function using basic input/output system (BIOS) programs.

A CMCI is an interrupt triggered by a correctable error and is used to predict component faults. After the CMCI function is enabled, the operating system (OS) collects correctable error information and corrects errors. This function is enabled by default.

Impact on the System

This operation has no adverse impact on the system.

Prerequisites

Conditions

You have accessed basic input/output system (BIOS). For details, see 2.1 .

Data

Data preparation is not required for this operation.

Procedure

  1. Choose IntelRCSetup > Runtime Error Logging and press Enter.

    The Runtime Error Logging screen appears, as shown in Figure 3-1.

    Figure 3-1 Runtime Error Logging screen

  2. Select CMCI and press Enter, as shown in Figure 3-1.
  3. From the short-cut menu that appears, choose Enable to enable CMCI or choose Disable to disable CMCI.
  4. Press F10.

    The Exit Saving changes? dialog box appears.

  5. Select Yes to save the settings.