No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

RH5885 V3 Server V100R003 User Guide 30

This document describes the appearance, specifications, parameters, and structure of the RH5885 V3, and how to install an OS, replace parts, and install, remove, configure, and troubleshoot the server.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Sensor List

Sensor List

Sensor

Description

Remarks

Inlet Temp

Air inlet temperature

Right mounting ear

PCH Temp

PCH temperature

Component in position U1196 on the mainboard.

CPUN Core Rem

CPU core temperature

CPU. N indicates the CPU ID. The value ranges from 1 to 4.

CPUN DTS

CPU DTS value

CPUN Prochot

CPU Prochot

CPUN VDDQ Temp

CPU VDDQ temperature

CPU 1: Components in positions U1000 and U1315 on the mainboard.

CPU 2: Components in positions U1324 and U1325 on the mainboard.

CPU 3: Components in positions U1335 and U1336 on the mainboard.

CPU 4: Components in positions U1346 and U1347 on the mainboard.

N indicates the CPU ID. The value ranges from 1 to 4.

CPUN VRD Temp

CPU VRD temperature

CPU 1: Component in position U1272 on the mainboard.

CPU 2: Component in position U1280 on the mainboard.

CPU 3: Component in position U1288 on the mainboard.

CPU 4: Component in position U1296 on the mainboard.

N indicates the CPU ID. The value ranges from 1 to 4.

CPUN MEM Temp

CPU DIMM temperature

DIMM corresponding to the CPU. N indicates the CPU ID. The value ranges from 1 to 4.

SYS 5V

Mainboard 5.0 V voltage

Component in position U1298 on the mainboard.

SYS 3.3V

Mainboard 3.3 V voltage

Component in position U1297 on the mainboard.

Standby 5V

Mainboard standby 5.0 V voltage

Component in position U1229 on the mainboard.

Standby 3.3V

Mainboard standby 3.3 V voltage

Component in position U1070 on the mainboard.

Standby 2.5V

Mainboard standby 2.5 V voltage

Component in position U14 on the BMC card.

Standby 1.5V

Mainboard standby 1.5 V voltage

Component in position U16 on the BMC card.

MOS 1 Volt Drop

Voltage difference between the front and rear ends of the MOS tube of the 12 V soft-start circuit 1

Component in position U1361 on the mainboard.

MOS 2 Volt Drop

Voltage difference between the front and rear ends of the MOS tube of the 12 V soft-start circuit 2

Component in position U1362 on the mainboard.

RAID Temp

RAID controller card temperature

RAID controller card

FANN F Speed

Fan speed

Fan module. N indicates the fan module ID. The value ranges from 1 to 5.

FANN R Speed

Power

Server input power

Total PSU power.

PowerN

PSU input power

PSU. N indicates the PSU ID. The value ranges from 1 to 4.

CPUN Memory

DIMM status check

DIMM corresponding to the CPU. N indicates the DIMM ID. The value ranges from 1 to 4.

CPUN Status

CPU status, including the installation status, thermtrip, CAT error, BIST, and disabled

CPU. N indicates the CPU ID. The value ranges from 1 to 4.

CPUN QPI Link

CPU QPI status detection

CPUN Core

CPU core status detection

PwrOk Sig. Drop

Voltage drop status

BMC Card

PSN Presence

PSU presence status

BMC card. N indicates the BMC card ID. The value ranges from 1 to 4.

PSN Status

PSU fault status

PSU. N indicates the PSU ID. The value ranges from 1 to 4.

PSN Fan Status

PSU fan status

Power Button

Power button

Right mounting ear

UID Button

UID button status

DISKN

Disk status

Hard disk. N indicates the physical disk slot number.

FANN F Presence

Fan presence

Drive backplane. N indicates the drive backplane ID. The value ranges from 1 to 5.

FANN R Presence

FANN F Status

Fan fault status

Fan module. N indicates the fan module ID. The value ranges from 1 to 5.

FANN R Status

RAID Presence

RAID controller card presence status

Component in position U1081 (CPLD 1) on the mainboard.

Riser Card

Entity presence

Component in position U1082 (CPLD 2) on the mainboard.

RTC Battery

RTC battery status

CMOS battery

RAID Status

RAID controller card health status

RAID controller card

RAID PCIe ERR

RAID controller card health status

DIMMN

DIMM status

DIMM. N indicates the DIMM slot number.

SSDN Temp

ES3000 V2 temperature

This sensor is available only when an ES3000 V2 is connected. N indicates the ID.

SSD DiskN Temp

SSD Temperature

SSD. N indicates the physical disk slot number.

SDN CARD

SD card presence status, health status, logical group status, rebuilding status, and reconstruction cancellation

SD card. N indicates the SD card ID. The value is 1 or 2.

No SD Card

No SD card

N/A

N indicates the ID of the component.

ACPI State

ACPI status

SysFWProgress

System software process and system startup error

SysRestart

System restart cause

Boot Error

Boot error

Watchdog2

Watchdog

Mngmnt Health

Management subsystem health status

SAS Cable

Entity presence

PCIe Status

PCIe status error

PwrOn TimeOut

Power-on timeout

PwrCap Status

Power capping status

HDD Backplane

Entity presence

HDD BP Status

Disk backplane health status

NICN Status

NIC health status

PortN Link Down

Network port link state.

No SD Card

SD card status

System Notice

Hot restart notice. Collect error information for the fault diagnosis program.

System Error

System suspension or restart. Check the background logs.

PCH Status

PCH chip fault diagnosis health status

PS Redundancy

Redundancy failure due to PSU removal

BMC Boot Up

BMC startup event

SEL Status

SEL full or clearing events

Op. Log Full

Operation log full or clearing events

Sec. Log Full

Security log full or clearing events

CPU NUM Config

The number of CPUs does not meet the requirement.

CPU Match

The CPU type does not match.

BMC Time Hopping

Time hopping

NTP Sync Failed

NTP synchronization failure and recovery events