RH5885 V3 Server V100R003 User Guide 30

This document describes the appearance, specifications, parameters, and structure of the RH5885 V3, and how to install an OS, replace parts, and install, remove, configure, and troubleshoot the server.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing the PSU Backplane

Installing the PSU Backplane

  1. Power off the server. For details, see Powering On and Off the RH5885 V3. Remove all power cables.
  2. Remove all PSUs from the RH5885 V3. For details, see Removing a PSU.
  3. Remove the mainboard from the RH5885 V3. For details, see Removing the Mainboard.
  4. Wear an ESD wrist strap or ESD gloves. For details, see Safety Instructions.
  5. Take the spare PSU backplane out of the ESD bag.
  6. Align the holes on the PSU backplane with the two screws shown in Figure 5-110, and move the PSU backplane in the arrow direction as far as it will go. See step (1) in Figure 5-110.

    Figure 5-110 Installing the PSU backplane

  7. Screw the PSU backplane. See step (2) in Figure 5-110.
  8. Connect all cables to the PSU backplane.
Translation