No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

RH5885 V3 Server V100R003 User Guide 30

This document describes the appearance, specifications, parameters, and structure of the RH5885 V3, and how to install an OS, replace parts, and install, remove, configure, and troubleshoot the server.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing the Hard Disk Backplane (12-Bay Server)

Installing the Hard Disk Backplane (12-Bay Server)

  1. Power off the server. For details, see Powering On and Off the RH5885 V3. Remove all power cables.
  2. Remove the chassis cover of the RH5885 V3. For details, see Removing the Chassis Cover.
  3. Remove all hard disks from the RH5885 V3. For details, see Removing a SATA HDD, SAS HDD, or SSD.
  4. Remove all fan modules from the RH5885 V3. For details, see Removing a Fan Module.
  5. Remove the air duct of the RH5885 V3. For details, see Removing the Air Duct.
  6. Remove the beam of the RH5885 V3. For details, see Removing the Beam.
  7. Wear an ESD wrist strap or ESD gloves. For details, see Safety Instructions.
  8. Take the spare hard disk backplane out of its ESD bag.
  9. Connect the hard disk backplane to the mainboard, RAID controller card, and PCIe adapter using cables. See step (1) in Figure 5-92.

    For details about the cable connections, see "Internal Cabling" of each server model in Product Overview. Connect the SSD0, SSD1, SSD2, and SSD3 ports on the hard disk backplane to the SSD0, SSD1, SSD2, and SSD3 ports on the PCIe adapter using cables respectively.

    Figure 5-92 Installing the hard disk backplane

  10. Hook the hard disk backplane, and move it downwards as far as it will go. See step (2) in Figure 5-92.
  11. Tighten the screws on the hard disk backplane. See step (3) in Figure 5-92.