Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Using the WebUI of MM910 Earlier Than (U54) 2.20 to Collect Information

Using the WebUI of MM910 Earlier Than (U54) 2.20 to Collect Information

Scenarios

Use the WebUI of MM910 earlier than (U54) 2.20 to collect logs in one-click mode.

Procedure

  1. Log in to the MM910 WebUI. For details, see Logging In to the MM910 WebUI.
  2. Choose System Management on the menu bar, choose SEL Information in the navigation tree, and click the SMM tab and then the One touch collect tab.

    The log collection page is displayed.

  3. Choose Full Collect > Startup to start log collection.

    Log collection takes about 20 minutes. When log collection is complete, a log file named one_touch_info_all.tar.gz is displayed in the File Name area.

  4. Click the log file name and download it to the local PC as prompted.

    NOTE:

    For MM910 earlier than (U54) 2.20, collect logs of both the active and standby management modules.