Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
V3

V3

Common Problems of the Management Software

Events Reported by the SNMP Trap Cannot Be Resolved by the MIB Library
Problem Description
Table 5-248 Basic information

Item

Common Problems of RAID Controller Cards and Hard Drives

Information

Source of the Problem

iBMC

Intended Product

All servers

Release Date

2016-01-18

Keyword

SNMP trap

Symptom

Description related to the events received by the SNMP trap cannot be found in the MIB library.

Key Process and Cause Analysis

On the iBMC, the SNMP trap mode is set to the event code mode. Therefore, all the OIDs of the events reported on the iBMC are 1.3.6.1.4.1.2011.23.2.1.

Conclusion and Solution

On the iBMC WebUI, choose Alarm&SEL>Alarm Settings and set SNMP Trap to OID.