Huawei Server Maintenance Manual 09

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking Indicators to Locate Faults

Checking Indicators to Locate Faults

You can check indicators to locate faults. For details about the positions of the indicators, see the "Appearance" section in the user guide of the specific server.

Process

Figure 3-8 shows the process for checking the indicators.

Figure 3-8 Process for checking the indicators
  1. Observe the status indicators of the servers.

    Table 3-27 Status indicators

    Indicator

    Status

    Meaning

    Diagnosis Procedure

    Health indicator (HLY)

    Steady green

    The server is operating properly.

    N/A

    Blinking red

    A fault alarm is generated.

    1. Log in to the iBMC WebUI to view the alarm information.
    2. (Optional) View the error code on the fault diagnosis LED located on the front panel.

    Power indicator (PWR)

    Steady green

    The server is powered on.

    N/A

    Blinking yellow

    The iBMC management system is being started. In this case, you cannot power on or off the server by pressing the power button.

    Steady yellow

    The server is ready to power on.

    Press the power button to power on the server. If the server cannot be powered on, log in to the iBMC WebUI and view the alarm to rectify the fault.

    Off

    The server is not connected to a power source.

    1. If the iBMC WebUI is accessible, log in and check for any alarms.
    2. If the iBMC WebUI is inaccessible, check whether the power supply to the server is normal and whether the power supply units (PSUs) are normal.

    UID indicator

    Steady blue

    The server is being located.

    NOTE:

    The UID indicator is located on the UID button. The UID indicator displays a steady blue light to help identify and locate a server. To turn on or off the UID indicator, you can manually press the UID button or run commands on the iBMC CLI.

    To reset iMana 200 or iBMC, hold down the UID button for 4 to 6 seconds.

    Off

    The server is not being located or is not connected to a power source.

  2. View iBMC system event logs (SELs) to locate faults.
  3. Observe indicators on server components.

    Table 3-28 Drive status indicators

    Drive Activity Indicator

    Drive Fault Indicator

    Meaning

    Diagnosis

    Steady green

    Off

    The drive is operating properly.

    No corrective action is required.

    Blinking green

    Data is being read from or written to the drive.

    Steady green

    Blinking yellow

    The drive is located or RAID is being rebuilt.

    Blinking green

    Steady green, blinking green, or off

    Steady yellow

    The drive is faulty.

    Log in to iBMC, and use FusionServer Tools Toolkit to check for any drive fault.

    Off

    Off

    The drive is faulty or not detected.

    Check whether the drive is in good contact, or log in to iBMC and use FusionServer Tools Toolkit to check for any drive fault.

    Table 3-29 PSU status indicators

    Indicator

    Status

    Meaning

    Diagnosis

    PSU operating status indicator (460 W/750 W)

    Steady green

    The power supply is normal.

    N/A

    Off

    The PSU has no power, or the system is on standby or abnormal.

    Check whether the power cable is connected properly to the PSU and whether the PSU is normal.

    Table 3-30 Network port indicators

    Indicator

    Status

    Meaning

    Diagnosis

    Network port link indicator

    Steady green

    The network port is connected properly.

    N/A

    Off

    The network port is not connected properly or the network port is not in use.

    1. Connect the network port to another switch and to another network cable to check whether the original switch and network cable are faulty.
    2. Check whether the NIC is properly operating.

    Optical port data transmission status indicator

    Blinking orange

    Data is being transmitted.

    N/A

    Off

    No data is being transmitted.

    Optical port connectivity status indicator

    Steady green

    The network connectivity is normal.

    Off

    The network port is not connected.

    1. Connect the network port to another switch, optical cable, and optical module to determine whether the switch and optical cable are functioning correctly and whether the optical module is of the correct type and speed.
    2. Check the NIC status in the OS.
    3. Check whether the ports on the switch and NIC are up.

    Data transmission status indicator for the management network port

    Blinking yellow

    Data is being transmitted.

    N/A

    Off

    No data is being transmitted.

    Connectivity status indicator for the management network port

    Steady green

    The network connectivity is normal.

    Off

    The network port is not connected.

    1. Connect the network port to another switch and to another network cable to determine whether the switch and network cable are functioning correctly.
    2. Check whether the NIC is properly operating.