Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling Master/Slave Switchover

Enabling Master/Slave Switchover

To implement backup between master and standby switches in a stack with multiple switches, enable the master/slave switchover function to allow the original standby switch to become the new master switch.

Context

In a stack containing multiple switches, you can manually perform a switchover between the master and standby switches during software upgrade or system maintenance. After the master/slave switchover is complete, the original master switch restarts and joins the stack, and the original standby switch becomes the new master switch.

Before a master/slave switchover, check whether the stack is ready for a switchover. The master/slave switchover can be performed only when the stack meets switchover requirements.

Procedure

  1. (Optional) Run:

    display switchover state

    Information about master and slave switchover is displayed, which helps check whether the stack meets switchover requirements.

    You can perform a master/slave switchover only when the Switchover State field displays Ready.

  2. Run:

    system-view

    The system view is displayed.

  3. Run:

    slave switchover enable

    Master/slave device switchover is enabled.

    By default, master/slave switchover is enabled.

  4. Run:

    slave switchover

    A master/slave switchover is performed.