Scenario: DIN Rail Mounting
Context
This installation method applies to the S5735I-S8T4SN-V2, S5735I-S8T4XN-V2, S5735I-S8T4XN-T-V2, and S5735I-S8U4XN-V2.
Make sure the following prerequisites are met before the installation:
- The DIN rail has been secured in position.
- The switch is placed near the DIN rail for convenient movement.
When multiple S5735I-S8T4SN-V2 switches are installed on the same DIN rail, there must be a clearance of at least 88 mm between two neighboring switches. The clearance above a switch must be at least two times the switch's height and that below must be greater than or equal to the switch's height.
When multiple S5735I-S8T4XN-V2, S5735I-S8T4XN-T-V2, and S5735I-S8U4XN-V2 switches are installed on the same DIN rail, there must be a clearance of at least 66 mm between two neighboring switches. The clearance above a switch must be at least two times the switch's height and that below must be greater than or equal to the switch's height.
Procedure
- Place the switch's rear panel in front of the DIN rail and ensure that the DIN rail fits in between the fixture near the top of the switch and spring latch near the bottom.
- Make the switch incline forward with the bottom away from the DIN rail, and place the fixture on the top of the DIN rail.
- Slowly push the switch toward the DIN rail to make the spring latch at the rear of the switch move down. The spring latch then bounces back to fix the switch on the DIN rail.
If the spring latch is too tight to move down, you can pull down the spring latch during the installation.
You can also take fixing measures in the horizontal direction of the switch.