S12700 Series Agile Switches Hardware Description

This document describes hardware components of the S12700, including the cabinet, chassis, power supply facilities, fan modules, cards, cables, and pluggable modules for interfaces. You can find useful information about S12700 hardware components from this document.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EH1D2VS08000-8-Port 10G Cluster Switching System Service Unit (SFP+)

EH1D2VS08000-8-Port 10G Cluster Switching System Service Unit (SFP+)

Version Mapping

Table 7-77  Switch chassis and software versions matching the card

Card Name

S12704 Chassis

S12708 and S12712 Chassis

S12710 Chassis

EH1D2VS08000

Supported in V200R008C00 and later versions

Supported in V200R005C00 and later versions

Not supported

Introduction

The EH1D2VS08000 provides eight 10GE optical ports, which can only be used for cluster connection and cannot be used for data transmission and switching.

The EH1D2VS08000 can be installed in the subcard slot of an ET1D2SFUA000, ET1D2SFUC000 or ET1D2SFUD000.

Figure 7-41  Appearance of the EH1D2VS08000

Functions

Switches connected through optical ports on the EH1D2VS08000 cards form a cluster switch system (CSS) and are considered as one device. You can log in to the master switch to manage all the switches in the CSS.

Usage Constraints

The EH1D2VS08000 is hot swappable in the S12700.

Indicators and Ports

Figure 7-42  Indicators on the EH1D2VS08000 panel

Table 7-78  Indicators on the EH1D2VS08000 panel

Number

Indicator

Color

Description

1

RUN/ALM: running status indicator

Green

Steady on: The card has been powered on, but the software is not running.

Slow blinking: The card software is running properly.

Fast blinking: The card software is starting.

Red

Steady on: The card has failed and the fault requires manual intervention.

Yellow

Steady on: The card is powered off.

2

MASTER: master/slave status indicator

Green

Steady on: The chassis with the EH1D2VS08000 card installed is the master chassis of the CSS.

Off: The chassis with the EH1D2VS08000 card installed is not the master chassis of the CSS.

3

LINK/ALM

Green

Steady on: The link status of the CSS port is Up.

Red

Steady on: The cable is connected incorrectly to the CSS port.

-

Off: The link status of the CSS port is Down.

Figure 7-43  Ports on the EH1D2VS08000 panel

1 Eight 10G BASE-SFP+ optical ports
10G BASE-SFP+ optical port

Table 7-79 lists the attributes of a 10G BASE-SFP+ optical port.

Table 7-79  10G BASE-SFP+ optical port attributes
Attribute Description
Connector type SFP+
Optical port attribute
Ports on each EH1D2VS08000 card are divided into two groups: group 1 with ports 1, 2, 3, and 4, and group 2 with ports 5, 6, 7, and 8. When chassis 1 and chassis 2 need to set up a cluster, connect their CSS cards according to the following rules:
  • Each CSS card can be connected to only one CSS card in the other chassis and cannot be connected to a CSS card in the local chassis.
  • The ports in group 1 of one cluster card can only connect to the ports in group 1 of another cluster card. This rule also applies to the ports in group 2.
  • The two chassis must be connected by at least one cluster cable.
  • The numbers of cluster cables connected to all the cluster cards must be the same and must be an even number. If the numbers are different, the total cluster bandwidth is lowered.
To ensure good cable arrangement for convenient maintenance, you are advised to connect the CSS cards in the following way, as shown in Figure 7-44:
  • Connect ports in one chassis to the ports with the same port numbers in the other chassis.
  • Install at least two CSS cards in each chassis.
Figure 7-44  Cable connections on EH1D2VS08000 cards (only applicable to S12700 switches)

Specifications

Table 7-80  EH1D2VS08000 specifications

Item

Description

Physical specifications

  • Dimensions (W x D x H): 213.0 mm x 151.8 mm x 35.1 mm (8.4 in. x 6.0 in. x 1.4 in.)
  • Weight: 0.50 kg (1.10 lb)
  • Maximum power consumption: 30 W

Environment specifications

  • Operating temperature: 0°C to 45°C (32°F to 113°F)
  • Operating relative humidity: 5% RH to 95% RH (noncondensing)
  • Storage temperature: -40°C to +70°C (-40°F to +158°F)
  • Storage relative humidity: 5% RH to 95% RH (noncondensing)

Ordering Information

Card ordering information is subject to updates with product version upgrades. The ordering information provided in this manual is for reference only. To obtain the latest ordering information, contact Huawei switch distributors or Huawei local office.

Table 7-81  Ordering information
Part Number Card Description Card Model
03021UWH

8-Port 10G Cluster Switching System Service Unit (SFP+)

EH1D2VS08000

Translation
Download
Updated: 2019-05-15

Document ID: EDOC1000047496