S12700 Series Agile Switches Hardware Description

This document describes hardware components of the S12700, including the cabinet, chassis, power supply facilities, fan modules, cards, cables, and pluggable modules for interfaces. You can find useful information about S12700 hardware components from this document.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ET1D2MPUA000-S12704/S12708/S12712 Main Processing Unit A (Optional Clock)

ET1D2MPUA000-S12704/S12708/S12712 Main Processing Unit A (Optional Clock)

Version Mapping

Table 7-4  Switch chassis and software versions matching the card

Card Name

S12704 Chassis

S12708 and S12712 Chassis

S12710 Chassis

ET1D2MPUA000

Supported in V200R008C00 and later versions

Supported in V200R005C00 and later versions

Not supported

Introduction

The ET1D2MPUA000 is the main control unit for the S12704, S12708 and S12712. It provides the control plane and management plane for the entire system and reserves a slot for clock daughter card.

The ET1D2MPUA000 can be installed in:

  • Slots 05 and 06 in an S12704 chassis.
  • Slots 09 and 10 in an S12708 chassis.
  • Slots 13 and 14 in an S12712 chassis.
Figure 7-3  Appearance of the ET1D2MPUA000

Functions

The ET1D2MPUA000 provides the control plane and management plane for the entire system.

  • The control plane provides functions such as protocol processing, service processing, route calculation, forwarding control, service scheduling, traffic statistics collection, and system security.
  • The management plane is responsible for system status monitoring, environment monitoring, log and alarm processing, system software loading, and system upgrades.

The ET1D2MPUA000 consists of the following functional modules:

  • Control module: functions as the control and management plane for the ET1D2MPUA000 and the entire system, implementing protocol processing, route calculation, forwarding control, system management, and system security.
  • Local clock module: provides the working clock for the chips of the control module, and device management and monitoring module on the ET1D2MPUA000.
  • Device management and monitoring module: provides functions of a controller area network (CAN) bus module to monitor the ET1D2MPUA000 and manage the CAN bus modules of LPUs.
  • Power supply module: provides power supply for the ET1D2MPUA000.
  • Value-added service module: provides enhanced services such as operation, administration and maintenance (OAM) and bidirectional forwarding detection (BFD).
Table 7-5  Functions of the ET1D2MPUA000
Function Description

Basic functions

The ET1D2MPUA000 is the system control and management unit for the S12704, S12708 and S12712. It integrates the main control unit, clock unit, and system maintenance unit.

OAM

The ET1D2MPUA000 supports the following OAM functions:
  • 802.1ag: identifies, detects, and sends continuity check (CC) packets.
  • Multiprotocol Label Switching (MPLS OAM): identifies, detects, and sends MPLS OAM packets.
  • OAM UNCFG_MEP.

Memory

4 GB

Flash

128 MB

eUSB card

2 GB

The system configuration data, startup files, system software package, and system logs are saved in the eUSB card by default.

Clock

The ET1D2MPUA000 can have LE0D00CKMA00 installed to provide stratum-3 clock, synchronous Ethernet, and IEEE 1588v2 functions in V200R010C00 and later versions.

Redundancy backup

1+1 hot standby

Main control board is mandatory for switches. Each switch must be configured with one or two main control boards. When one main control board is configured for a switch, the main control board can be installed in either main control board slot of the switch. When two main control boards are configured, the two main control boards work in hot standby mode to improve reliability of the switch. The active and standby main control boards monitor the status of each other. If the active main control board fails, the standby main control board automatically becomes active to ensure uninterrupted services.

Hot swapping

Supported

Before removing the active card, perform an active/standby switchover.

Usage Constraints

  • Main control units of different models cannot be used in the same chassis.

  • The fans in a switch work in intelligent speed adjustment mode after a switchover between the active and standby main control units in the switch. If the fans run at a specified speed before a switchover, run the set fan-speed command after the switchover to set the fan speed again.

Indicators and Ports

Figure 7-4  Indicators and buttons on the ET1D2MPUA000 panel

Table 7-6  Indicators and buttons on the ET1D2MPUA000 panel

Number

Indicator/Button

Color

Description

1

CSS ID

Green

There are eight CSS ID indicators on the panel, but only one is on at a time.
  • CSS ID N is steady on: The CSS ID of the local chassis is N.
  • All CSS ID indicators are off: The chassis is not running the CSS service.

2

CSS MASTER

Green

Steady on: The MPU is the master MPU of the CSS.

Off: The MPU is not the master MPU of the CSS.

3

USB

Green

Steady on: USB-based deployment of the card has been completed.

Fast blinking: The card is reading data from a USB flash drive.

Yellow

Steady on: The card has finished reading data from the USB flash drive. You can remove the USB flash drive now.

Red

Steady on: The card fails to connect to the network management system (NMS) or fails to register with the NMS.

Fast blinking: An error has occurred when the card is executing the configuration file or reading data from the USB flash drive.

-

Off: No USB flash drive is connected to the card, the USB port on the card is damaged, or the indicator is damaged.

4

SYNC

Green

Steady on: The switch supports time and clock synchronization, and a clock daughter card is installed on the MPU.

Off: The switch supports time and clock synchronization, but no clock daughter card is installed on the MPU.

5

LINK indicator of the GE0 optical port

NOTE:

These indicators are reserved.

6

ACT indicator of the GE0 optical port

7

ACT indicator of the GE0 electrical port

8

LINK indicator of the GE0 electrical port

9

Mini USB indicator

Green

Steady on: The Mini USB port on the card is active.

Off: The Mini USB port on the card is inactive.

10

ACT indicator of the ETH port

Yellow

Blinking: The port is transmitting and receiving data.

11

LINK indicator of the ETH port

Green

Steady on: A link has been established on the port.

12

RST button

-

Press this button to reset the card.

13

ACT: active/standby status indicator

Green

Steady on: The card is the active MPU of the switch.

Off: The card is the standby MPU of the switch.

14

RUN/ALM: running status indicator

Green

Steady on: The card has been powered on, but the software is not running.

Slow blinking: The card software is running properly.

Fast blinking: The card software is starting.

Red

Steady on: The switch has a 1600 W DC power module or 2400 W DC power module installed or experiences a card failure. Manual intervention is required.

Yellow

Steady on: The card is powered off. (For example, the card is starting.)

Figure 7-5  Ports on the ET1D2MPUA000 panel

1 One USB port. A USB flash drive can be inserted into this port to load the system software to the switch during device deployment.
2 Two BITS ports. The CLK1 and CLK2 ports on the MPU map the BITS0 and BITS1 ports on the clock daughter card. BITS devices or other products can connect to BITS ports to synchronize the time and clock.
3 Two GE ports (reserved)
4 One combo console port, consisting of a console port and a Mini USB port. The S12700 can connect to a configuration terminal through this port for onsite configuration.
5 One ETH management port (10M/100M BASE-TX auto-sensing). It can connect to a network port of a configuration terminal or network management workstation to set up a local or remote configuration environment.
ETH management port

The ETH management port connects the switch to a configuration terminal or network management workstation to set up a local or remote configuration environment. The port must be used with an Ethernet Cable. Table 7-7 describes the attributes of an ETH management port.

Table 7-7  ETH management port attributes
Attribute Description
Connector type RJ45
Standards compliance IEEE802.3

Working mode

10/100 Mbit/s auto-sensing

Full-duplex

Maximum transmission distance

100 m

Combo console port

The combo console port can connect to a configuration terminal for onsite configuration. The Mini USB port and the Console cannot be used at the same time. Use one of them according to the actual situation.

The console port must be used with a Console Cable. Table 7-8 describes the attributes of the console port.

Table 7-8  Console management port attributes
Attribute Description
Connector type RJ45
Working mode Duplex Universal Asynchronous Receiver/Transmitter (UART)
Standards compliance RS232

Baud rate

9600 bit/s to 115200 bit/s

Default value: 9600 bit/s

BITS port
Table 7-9  BITS port attributes

Attribute

Description

Connector type

RJ45

Working mode

Clock synchronization mode: full-duplex

Time synchronization mode: half-duplex

Frame format

  • 1 pps + time of day (ToD)
  • DC level shifter (DCLS)
  • 2 MHz
  • 2 Mbit/s: HDB3 code
  • 1.544 Mbit/s: B8ZS code

Standards compliance

  • 1 pps + ToD
    • NMEA-0183
    • ToD standard of China Mobile
  • DCLS: standard of DCLS signals
  • 2 MHz: G.703 standard
  • 2 Mbit/s: G.703 standard
  • 1.544 Mbit/s: G.703 standard

Cable used

Time synchronization mode: straight-through Ethernet cable (RS422 signal)

Clock synchronization mode: E1/T1 cable (120-ohm balanced cable)

For details about cable parameters, see Clock Cable.

USB Port

A USB flash drive can be inserted into the USB port to transfer configuration files, software packages, or other files required for the switch during device deployment. Table 7-10 lists the attributes of the USB port.

Table 7-10  Attributes of the USB port

Attribute

Description

Connector type

USB

Standards compliance

USB2.0

Specifications

Table 7-11  Specifications of the ET1D2MPUA000

Item

Description

Physical specifications

  • Dimensions (H x W x D): 35.1 mm x 394.7 mm x 426.8 mm (1.38 in. x 15.54 in. x 16.80 in.)
  • Weight: 2.88 kg (6.35 lb)
  • Maximum power consumption: 100 W (including subcards)

Environment specifications

  • Operating temperature: 0°C to 45°C (32°F to 113°F)
  • Operating relative humidity: 5% RH to 95% RH (noncondensing)
  • Storage temperature: -40°C to +70°C (-40°F to +158°F)
  • Storage relative humidity: 5% RH to 95% RH (noncondensing)

Ordering Information

Card ordering information is subject to updates with product version upgrades. The ordering information provided in this manual is for reference only. To obtain the latest ordering information, contact Huawei switch distributors or Huawei local office.

Table 7-12  Ordering information
Part Number Card Description Card Model

03030RPE

S12704/S12708/S12712 Main Processing Unit A (Optional Clock) ET1D2MPUA000
Translation
Download
Updated: 2019-06-21

Document ID: EDOC1000047496