S12700 Series Agile Switches Hardware Description

This document describes hardware components of the S12700, including the cabinet, chassis, power supply facilities, fan modules, cards, cables, and pluggable modules for interfaces. You can find useful information about S12700 hardware components from this document.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ET1D2SFUB000-S12700 Switch Fabric Unit B

ET1D2SFUB000-S12700 Switch Fabric Unit B

Version Mapping

Table 7-57 Switch chassis and software versions matching the card

Card Name

S12700 Chassis

ET1D2SFUB000

Supported in V200R010C00 and later versions

Introduction

The ET1D2SFUB000 can be installed in:
  • Slots 07 and 08 in S12704 chassis.
  • Slots 11 to 14 in S12708 chassis.
  • Slots 11 and 12 in S12710 chassis.
  • Slots 15 to 18 in S12712 chassis.
Figure 7-28 Appearance of the ET1D2SFUB000

Functions

The ET1D2SFUB000 provides the data plane for the entire system. The data plane provides high-speed, non-blocking data channels for data switching between service modules.

The ET1D2SFUB000 consists of the following functional modules:

  • Switching module: functions as the data plane and provides high-speed service channels for data switching.
  • Local clock module: provides the working clock for the chips of the switching module, management module, and monitoring module on the ET1D2SFUB000.
  • Power supply module: provides power supply for the ET1D2SFUB000.
Table 7-58 Functions of the ET1D2SFUB000
Function Description

Basic function

Core of data switching in the S12704, S12708, S12710, or S12712 system.

Clustering

10GE or optical 40GE ports on the card can be used for cluster connection.

Memory

512 MB

Flash

64 MB

Redundancy backup

N+1 hot standby

ET1D2SFUB000 cards in a chassis work in redundancy mode to improve system reliability. If one SFU fails, service traffic on this card will be switched to other SFUs to ensure uninterrupted services.

Hot swapping

Supported

Usage Constraints

A chassis can have only one type of SFUs installed.

Indicators and Ports

Figure 7-29 Indicators and buttons on the ET1D2SFUB000 panel

Table 7-59 Indicators and buttons on the ET1D2SFUB000 panel

Number

Indicator/Button

Color

Description

1

10GE optical port indicator (LINK/ALM)

Green

Steady on: The link status of the CSS port is Up.

Red

Steady on: Cable connection on the port is incorrect.

-

Off: The link status of the port is Down.

2

40GE optical port indicator (LINK/ALM)

Green

Steady on: The link status of all the internal four CSS ports is Up.

Yellow

Steady on: The link status of some of the internal four CSS ports is Up, and the link status of others is Down.

Red

Steady on: Cable connection on the port is incorrect.

-

Off: The link status of all the internal four CSS ports is Down.

3

OFL button

-

If there are at least two SFUs installed and running properly on a chassis with ET1D2SFUB000 (except S12710), before removing one SFU, hold down the OFL button on the SFU until the OFL indicator blinks red or turns steady red. When the OFL indicator turns steady red indicating that the SFU is isolated from the system, you can remove the SFU. When an SFU is running normally, its RUN/ALM indicator blinks green slowly and its OFL indicator is off.

4

OFL indicator

Red

Steady on: The SFU has been separated from the system and can be removed from the chassis.

Blinking: The SFU is being separated from the system and cannot be removed from the chassis.

Off: The SFU is running and cannot be removed from the chassis.

5

RUN/ALM: running status indicator

Green

Steady on: The card has been powered on, but the software is not running.

Slow blinking: The card software is running properly.

Fast blinking: The card software is starting.

Red

Steady on: The card has failed and the fault requires manual intervention.

Yellow

Steady on: The card is powered off. (For example, the card has been forcibly powered off using the power off command or is about to start.)

Figure 7-30 Ports on the ET1D2SFUB000 panel

1 Four 10GBASE SFP+ optical ports used for cluster connection between two chassis. They are multiplexed with the 40GE optical port. Either the 10GE ports or 40GE port can work at a time. By default, the four 10GBASE SFP+ optical port are used preferentially.
2 One 40GBASE-X optical port used for cluster connection between two chassis. It is multiplexed with the four 10GE optical ports.
10GBASE SFP+ optical port

Table 7-60 lists the attributes of a 10GE BASE-SFP+ optical port.

Table 7-60 Optical port attributes

Attribute

Description

Connector type SFP+
Optical port attributes

Depend on the SFP+ - SFP+ high-speed cable (1 m, 3 m, 5 m, 10 m), SFP+ optical module, or SFP+ optical cable used.

For the optical modules supported by the ET1D2SFUB000, see 10GE SFP+ Optical Modules (excluding the OSXD22N00) and 10GE-CWDM SFP+ Optical Modules.
Standards compliance IEEE 802.3ae
Frame format Ethernet_II, Ethernet_SAP, Ethernet_SNAP
Network protocol IP
40GBASE-X port

Table 7-61 lists attributes of a 40GBASE-X port.

Table 7-61 40GBASE-X port attributes
Attribute Description
Connector type QSFP+
Optical attributes

Depend on the QSFP+ optical module, QSFP+ - QSFP+ high-speed cable (1 m, 3 m, 5 m) or QSFP+ optical cable used.

For the optical modules supported by the ET1D2SFUB000 and their attributes, see 40GE QSFP+ Optical Modules (excluding the QSFP-40G-SR-BD).
Standards compliance IEEE802.3ba
Frame format Ethernet_II, Ethernet_SAP, Ethernet_SNAP
Network protocol IP
Each ET1D2SFUB000 card has two port groups: group 1 with 10GE ports 1-4 and group 2 with 40GE port 1. Two chassis can set up a cluster only when the following requirements are met:
  • One SFU can be connected to only one SFU in the other chassis. It cannot be connected to more than one SFU in the other chassis or to an SFU in the local chassis.
  • Ports in group 1 on one SFU can only be connected to ports in group 1 on the other SFU. In addition, ports in group 1 on an S12710 chassis must be connected sequentially based on their numbers. The port in group 2 on one SFU can only be connected to the port in group 2 on the other SFU.
  • The two chassis must be connected by at least one cluster cable.
  • If one chassis uses SFUB cards and the other chassis uses SFUA, SFUC, or SFUD cards, the four CSS ports on an SFUB card can only be connected to the four ports in group 1 on a VS08 CSS card (at any sequence).
To keep cluster cables neat and facilitate maintenance, you are advised to connect the two chassis according to Figure 7-31 or Figure 7-32:
  • Connect at least two cables on each SFU.
  • Install at least two SFUs in each chassis.
Figure 7-31 Cluster cable connections between ET1D2SFUB000 cards (method 1)
Figure 7-32 Cluster cable connections between ET1D2SFUB000 cards (method 2)

Specifications

Table 7-62 Specifications of the ET1D2SFUB000

Item

Description

Physical specifications

  • Dimensions (H x W x D): 35.1 mm x 394.7 mm x 426.8 mm (1.38 in. x 15.54 in. x 16.80 in.)
  • Weight: 3.25 kg (7.17 lb)
  • Maximum power consumption: 186.3 W

Environment specifications

  • Operating temperature: 0°C to 45°C (32°F to 113°F)
  • Operating relative humidity: 5% RH to 95% RH (noncondensing)
  • Storage temperature: -40°C to +70°C (-40°F to +158°F)
  • Storage relative humidity: 5% RH to 95% RH (noncondensing)

Ordering Information

Card ordering information is subject to updates with product version upgrades. The ordering information provided in this manual is for reference only. To obtain the latest ordering information, contact Huawei switch distributors or Huawei local office.

Table 7-63 Ordering information
Part Number Card Description Card Model

03031YLR

S12700 Switch Fabric Unit B

ET1D2SFUB000

Translation
Download
Updated: 2019-08-19

Document ID: EDOC1000047496

Views: 182736

Downloads: 1897

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next