No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0705FFFF Configuration Error (CPUN Status)

ALM-0x0705FFFF Configuration Error (CPUN Status)

Description

Alarm message:

Configuration error

The RH8100 V3 does not generate this alarm.

This alarm is generated when different types of CPUs or CPU incompatible with the server are detected during the server startup process.

Sensor triggering the alarm: CPUN Status

Attribute

Alarm ID Alarm Severity Auto Clear

0x0705FFFF

Critical

Yes

Parameters

Name Meaning
N

Serial number of the CPU.

Impact on the System

The system cannot operate properly, and services are interrupted.

Possible Causes

  • The server is configured with different models of CPUs.
  • The CPU is faulty.

  • The mainboard is faulty.

Procedure

  1. Check whether the server is configured with different models of CPUs.

    • If yes, go to 2.

    • If no, go to 3.

  2. Use the same model of CPUs. Then, check whether the alarm is cleared.

    For details about the CPUs supported by the server, see the Server Compatibility Checker.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Switch the CPU with a functioning CPU in the same chassis, and check whether the alarm is still generated for this CPU.

    • If yes, go to 4.

    • If no, go to 5.

  4. Replace the faulty CPU. Then, check whether the alarm is cleared.

    For details about how to replace the CPU, see "Replacing Parts" in the server user guide.

    • If yes, no further action is required.

    • If no, go to 5.

  5. Replace the mainboard. Check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 6.

  6. Contact Huawei technical support.
Download
Updated: 2019-06-04

Document ID: EDOC1000054724

Views: 267046

Downloads: 2985

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next