Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0840FFFF Device Removed / Device Absent (FANN F Presence/FANN R Presence)

ALM-0x0840FFFF Device Removed / Device Absent (FANN F Presence/FANN R Presence)

Description

Alarm message:

Device Removed / Device Absent

This alarm is generated when a specified fan module is not detected.

Sensor triggering the alarm:

  • FANN F Presence

  • FANN R Presence

Attribute

Alarm ID Alarm Severity Auto Clear

0x0840FFFF

Major

Yes

Parameters

Name Meaning
N Serial number of the fan.

Impact on the System

The system heat dissipation is affected, and the performance of the components on the mainboard deteriorates.

Possible Causes

  • The fan module is removed.

  • The fan module is not properly installed.

Procedure

  1. Check whether the alarmed fan module is removed.

    • If yes, go to 2.

    • If no, go to 3.

  2. Install the fan module properly. Check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Remove and reinstall the fan module. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  4. Replace the fan module. Check whether the alarm is cleared.

    For details about how to replace the fan module, see "Replacing Parts" in the server user guide.

    • If yes, no further action is required.

    • If no, go to 5.

  5. Contact Huawei technical support.