Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x32000007 Rapid Increase of PHY Bit Errors on the Link Between Expander Controllers (Expander, Major Alarm)

ALM-0x32000007 Rapid Increase of PHY Bit Errors on the Link Between Expander Controllers (Expander, Major Alarm)

Description

Alarm message:

The PHY bit errors of the link between arg1 (arg2arg3) and arg4 (arg5arg6) increased too fast.

This alarm is generated when data is transmitted on the link between two expander controllers and the detected PHY bit errors increase rapidly.

NOTE:

Expander controllers of different servers are located on different components, such as hard disk backplanes, mainboards, and GPU boards. For details, see the user manual of each server.

Alarm object: expander

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x32000007

Major

Yes

Parameters

Name

Meaning

arg1, arg4

Component where the expander controller related to the alarm is located, for example, Mainboard or GpuBoard.

arg2, arg5

Type of the expander controller related to the alarm, for example, SAS Expander.

arg3, arg6

ID of the expander controller related to the alarm.

Impact on the System

The devices on the link, such as the RAID controller card, expander controller, and hard disk, may be affected.

Possible Causes

  • The cable is not securely connected or the cable connection is incorrect.
  • The cable is faulty.
  • The components where the expander controllers are located are faulty.

Procedure

  1. Reconnect the cable between the components where the expander controllers are located, and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 2.

  2. Replace the cable, and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Replace the components where the expander controllers are located, and check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 4.

  4. Contact Huawei technical support.