Huawei Rack Server iBMC Alarm Handling 27

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2C00003D CPU Boards Mismatch (System, Major Alarm)

ALM-0x2C00003D CPU Boards Mismatch (System, Major Alarm)

Description

Alarm message:

Inconsistent models of CPU boards. 

This alarm is generated when different types of CPU boards are detected in a server.

Alarm object: system

Attribute

Alarm ID Alarm Severity Auto Clear

0x2C00003D

Major

Yes

Parameters

Name Meaning

-

-

Impact on the System

Some CPUs cannot be used, and the system performance is affected.

Possible Causes

Different types of compute nodes are used together.

Procedure

  1. Check whether the server is configured with the same model of SCMs, which hold the CPUs.

    • If yes, go to 3.

    • If no, go to 2.

  2. Use the same model of SCMs. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Contact Huawei technical support.