No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Error Code Handling

Error Code Handling

The error code displayed on the fault diagnosis LED on the front panel of a server indicates a hardware fault of the server. This topic describes the error codes and the procedure of rectifying faults.

Context

When a key component is faulty, the server fault diagnosis LED displays an error code to facilitate fault locating.

Servers RH1288 V3, RH2288 V3, RH2288H V3, RH5885 V3, 5288 V3, 1288H V5, 2288H V5, 2488 V5, 2488H V5, and 5885H V5 provide the fault diagnosis LED. Generally, the fault diagnosis LED is located on the front panel of the server. For details about its position, see the user guide of the server you use.

Procedure

  1. View the error code on the fault diagnosis LED.
  2. Log in to the iBMC WebUI of the server, and locate the alarm based on the error code.
  3. Rectify the fault.
  4. After the fault is rectified, check that the error code is not longer displayed on the fault diagnosis LED.

Error Code Reference

Table 2-1 Error code reference of Huawei V3 servers

Module

Error Code

Fault Description

Related Alarms

-

---

The server is operating properly.

-

CPU

C0N

NOTE:

N indicates the serial number of the CPU.

CPU N is malfunctioning or faulty.

DIMM

XYZ

NOTE:

XYZ indicates the serial number of the DIMM.

DIMM XYZ is malfunctioning or faulty.

ALM-0x01000001 Memory Overtemperature (Memory, Major Alarm)

XYF

NOTE:

X indicates the serial number of the CPU, and Y indicates the serial number of the CPU channel.

The channel Y of CPU X is malfunctioning or faulty.

Temperature

A00

The air inlet temperature is out of the operating temperature range of the server.

A0N

NOTE:

N indicates the serial number of the CPU.

The temperature of CPU N is out of its operating temperature range.

Power supply unit (PSU)

P0N

NOTE:

N indicates the serial number of the PSU.

PSU N is malfunctioning or faulty.

Fan module

F0N

NOTE:

N indicates the serial number of the fan module.

Fan module N is malfunctioning or faulty.

Mainboard

b01

The power supply to the mainboard is abnormal.

b02

The RAID controller card is malfunctioning or faulty.

L01

The cable is not securely or correctly connected.

E01

The CMOS battery is abnormal.

ALM-0x1000000D Low Voltage in Mainboard RTC Battery (Mainboard, Major Alarm)

Hard disk

HXY

NOTE:

XY indicates the slot number of the front hard disk.

The hard disk in slot XY is malfunctioning or faulty.

HAN

NOTE:

N indicates the slot number of the rear hard disk.

The rear hard disk in slot AN is malfunctioning or faulty.

HbN

NOTE:

N indicates the slot number of the rear hard disk.

The rear hard disk in slot BN is malfunctioning or faulty.

dXY

NOTE:

XY indicates the slot number of the rear hard disk.

The rear hard disk in slot XY is malfunctioning or faulty.

LOM

n01

The LAN on motherboard (LOM) is malfunctioning or faulty.

ALM-0x0D000001 NIC MCE/AER Error (NIC, Critical Alarm)

PCIe card

q0N

NOTE:

N indicates the serial number of the PCIe card.

The PCIe card in slot N is malfunctioning or faulty.

Hard disk backplane

BP1

The power supply to the front hard disk backplane is abnormal.

ALM-0x05000001 Disk Backplane Power Failure (Disk Backplane, Major Alarm)

BP2

The power supply to the built-in hard disk backplane is abnormal.

ALM-0x05000001 Disk Backplane Power Failure (Disk Backplane, Major Alarm)

BP3

The power supply to the rear hard disk backplane is abnormal.

ALM-0x05000001 Disk Backplane Power Failure (Disk Backplane, Major Alarm)

Table 2-2 Error code reference of V5 servers

Module

Error Code

Fault Description

Related Alarms

-

---

The server is operating properly.

-

CPU

C0N

NOTE:

N indicates the serial number of the CPU.

CPU N is malfunctioning or faulty.

DIMM

XYZ

NOTE:

XYZ indicates the serial number of the DIMM.

DIMM XYZ is malfunctioning or faulty.

ALM-0x01000001 Memory Overtemperature (Memory, Major Alarm)

Temperature

A00

The air inlet temperature is out of the operating temperature range of the server.

A0N

NOTE:

N indicates the serial number of the CPU.

The temperature of CPU N is out of its operating temperature range.

Power supply unit (PSU)

U00

The standby power supply is abnormal.

U10

The non-standby power supply is abnormal.

UCN

NOTE:

N indicates the serial number of the CPU.

CPU N is malfunctioning or faulty.

UP0

The PCH power supply is abnormal.

P0N

NOTE:

N indicates the serial number of the PSU.

PSU N is malfunctioning or faulty.

Fan module

F0N

NOTE:

N indicates the serial number of the fan module.

Fan module N is malfunctioning or faulty.

Mainboard

b01

The power supply to the mainboard is abnormal.

b02

The RAID controller card is malfunctioning or faulty.

L01

The cable is not securely or correctly connected.

E01

The CMOS battery is abnormal.

ALM-0x1000000D Low Voltage in Mainboard RTC Battery (Mainboard, Major Alarm)

Hard disk

HXY

NOTE:

XY indicates the serial number of the hard disk.

Hard disk XY is malfunctioning or faulty.

HAN

NOTE:

N indicates the slot number of the rear hard disk.

The rear hard disk in slot AN is malfunctioning or faulty.

HbN

NOTE:

N indicates the slot number of the rear hard disk.

The rear hard disk in slot BN is malfunctioning or faulty.

dXY

NOTE:

XY indicates the slot number of the rear hard disk.

The rear hard disk in slot XY is malfunctioning or faulty.

LOM

n01

The LOM is malfunctioning or faulty.

ALM-0x0D000001 NIC MCE/AER Error (NIC, Critical Alarm)

PCIe Card

q0N

NOTE:

N indicates the serial number of the PCIe card.

PCIe card N is malfunctioning or faulty.

Hard disk backplane

BP1

The power supply to the front hard disk backplane is abnormal.

ALM-0x05000001 Disk Backplane Power Failure (Disk Backplane, Major Alarm)

BP2

The power supply to the built-in hard disk backplane is abnormal.

ALM-0x05000001 Disk Backplane Power Failure (Disk Backplane, Major Alarm)

BP3

The power supply to the rear hard disk backplane is abnormal.

ALM-0x05000001 Disk Backplane Power Failure (Disk Backplane, Major Alarm)

Download