No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x08000063 Optical Module on the PCIe Card Overtemperature (PCIe Card, Minor Alarm)

ALM-0x08000063 Optical Module on the PCIe Card Overtemperature (PCIe Card, Minor Alarm)

Description

Alarm message:

The [arg1] arg2 optical module [arg3] temperature (arg4 degrees C) exceeds the overtemperature threshold (arg5 degrees C). 

This alarm is generated when the optical module temperature on a PCIe card exceeds the overtemperature threshold. This alarm is cleared when the optical module temperature is within the normal range.

Alarm object: PCIe card

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x08000063

Minor

Yes

Parameters

Name

Meaning

arg1

PCIe card holding the optical module, for example, FIO.

arg2

Name and slot No. of the PCIe card, for example, PCIe Card 3.

arg3

Port No. of the optical module, for example, 1 or 2.

arg4

Current reading of the sensor.

arg5

Alarm threshold.

Impact on the System

Services related to the optical module are affected.

Possible Causes

  • A fan module is faulty.
  • The ambient temperature exceeds the normal range.
  • The air inlet or outlet is blocked.
  • The optical module is faulty.

Procedure

  1. Check whether there is a fan alarm.

    • If yes, go to 2.
    • If no, go to 3.

  2. Replace the fan module. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Check whether the equipment room temperature exceeds the normal range.

    • If yes, go to 4.
    • If no, go to 5.

  4. Reduce the equipment room temperature to the normal range. After 5 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. Check whether the server air inlet or outlet is blocked.

    • If yes, go to 6.
    • If no, go to 7.

  6. Clear the blockage. After 5 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 7.

  7. Replace the optical module. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 8.

  8. Contact Huawei technical support.
Download
Updated: 2019-06-04