FusionServer Pro Rack Server iBMC Alarm Handling 31

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2C00002B Power-On Timed Out (System, Major Alarm)

ALM-0x2C00002B Power-On Timed Out (System, Major Alarm)

Description

Alarm message:

The [arg1] power [arg2] failure results host power-on timed out.

This alarm is generated when the server failed to power on within the specified time due to a power supply fault.

Alarm object: system

Attribute

Alarm ID Alarm Severity Auto Clear

0x2C00002B

Major

Yes

Parameters

Name Meaning

arg1

Serial number of the power supply, for example, LPM1.

arg2

Power supply subsystem name. For example, STBY_5V0 or STBY_1V8_PCH.

Impact on the System

The server cannot start.

Possible Causes

  • The external power supply does not meet power consumption requirements of the server.
  • The mainboard is faulty.

Procedure

  1. Check whether the external power supply meets power consumption requirements of the server.

    • If yes, go to 2.

    • If no, go to 3.

  2. Remove the power cable to power off the server, and then reconnect the power cable to power on the server. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  3. Replace the faulty components based on Table 2-3. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  4. Contact Huawei technical support.

Related Information

Table 2-3 Related Information

No.

Alarm Message

Involved Components

1

The power STBY_5V0 failure results host power-on timed out.

  1. Mainboard
  2. LCD

2

The power STBY_1V8_PCH failure results host power-on timed out.

Mainboard

3

The power STBY_1V05_PCH failure results host power-on timed out.

Mainboard

4

The power STBY_0V83_X557 failure results host power-on timed out.

Mainboard

5

The power STBY_1V2_X557 failure results host power-on timed out.

Mainboard

6

The power STBY_2V1_X557 failure results host power-on timed out.

Mainboard

7

The power STBY_2V5_X557 failure results host power-on timed out.

Mainboard

8

The power V_VCC_12V0_1 failure results host power-on timed out.

  1. Mainboard
  2. Fan
  3. CPU
  4. DIMM

9

The power V_VCC_12V0_2 failure results host power-on timed out.

  1. Mainboard
  2. Drive backplane
  3. RAID controller card
  4. Riser card

10

The power V_VCC_5V0 failure results host power-on timed out.

Mainboard

11

The power V_VCC_3V3 failure results host power-on timed out.

  1. Mainboard
  2. RAID
  3. Riser card

12

The power V_VCCIN_CPU1 failure results host power-on timed out.

  1. Mainboard
  2. CPU

13

The power V_VCCIN_CPU2 failure results host power-on timed out.

  1. Mainboard
  2. CPU

14

The power V_VSA_CPU1 failure results host power-on timed out.

  1. Mainboard
  2. CPU

15

The power V_VSA_CPU2 failure results host power-on timed out.

  1. Mainboard
  2. CPU

16

The power V_VCCIO_CPU1 failure results host power-on timed out.

  1. Mainboard
  2. CPU

17

The power V_VCCIO_CPU2 failure results host power-on timed out.

  1. Mainboard
  2. CPU

18

The power V_VMCP_CPU1 failure results host power-on timed out.

  1. Mainboard
  2. CPU

19

The power V_VMCP_CPU2 failure results host power-on timed out.

  1. Mainboard
  2. CPU

20

The power V_VPP_ABC failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

21

The power V_VPP_DEF failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

22

The power V_VPP_GHJ failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

23

The power V_VPP_KLM failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

24

The power V_VDDQ_ABC failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

25

The power V_VDDQ_DEF failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

26

The power V_VDDQ_GHJ failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

27

The power V_VDDQ_KLM failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

28

The power V_VTT_ABC failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

29

The power V_VTT_DEF failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

30

The power V_VTT_GHJ failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

31

The power V_VTT_KLM failure results host power-on timed out.

  1. Mainboard
  2. DIMM
  3. CPU

32

The power V_1V0_CPU1 failure results host power-on timed out.

  1. Mainboard
  2. CPU

33

The power V_1V0_CPU2 failure results host power-on timed out.

  1. Mainboard
  2. CPU

34

The power STBY_2V5_BMC failure results host power-on timed out.

Mainboard

35

The power STBY_PCH_PVNN failure results host power-on timed out.

Mainboard

Download