FusionServer Pro Rack Server iBMC Alarm Handling 30

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x1A000019 BMC Heartbeat Abnormal (BMC, Major Alarm)

ALM-0x1A000019 BMC Heartbeat Abnormal (BMC, Major Alarm)

Description

Alarm message:

Abnormal heartbeat signal between the active and standby iBMCs. 

This alarm is generated when the communication between the active and standby iBMCs failed.

Alarm object: BMC

Attribute

Alarm ID Alarm Severity Auto Clear

0x1A000019

Major

Yes

Parameters

Name Meaning

-

-

Impact on the System

Configuration synchronization and switchovers between the active and standby iBMCs are affected.

Possible Causes

The iBMC board is faulty.

Procedure

  1. Restart the active iBMC and then the standby iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 2.

  2. Replace the active HFC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Replace the standby HFC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  4. Contact Huawei technical support.