Huawei Rack Server iBMC Alarm Handling 27

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0500000D Failed to Obtain Disk Backplane Detection Point Temperature (Disk Backplane, Minor Alarm)

ALM-0x0500000D Failed to Obtain Disk Backplane Detection Point Temperature (Disk Backplane, Minor Alarm)

Description

Alarm message:

Failed to obtain data of the arg1 disk backplane arg2 temperature detection point arg3 arg4 temperature.

This alarm is generated when the system failed to obtain the temperature at the detection point of the disk backplane.

Alarm object:disk backplane

Attribute

Alarm ID Alarm Severity Auto Clear

0x0500000D

Minor

Yes

Parameters

Name Meaning
arg1

Location of the disk backplane, for example, Front, Inner, or Rear.

arg2

Number of the disk backplane, for example, 1 or 2.

arg3

Name of the temperature detection point, for example, 1 or 2.

arg4

Location of the temperature detection point, for example, near disk0 or near disk1.

Impact on the System

The temperature cannot be monitored. No alarm will be reported when the temperature is not in the normal range.

Possible Causes

The sensor chip has failed or the sensor access channel is unavailable.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 2

  2. Remove and reinstall the power cable or board. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Contact Huawei technical support.