Huawei Rack Server iBMC Alarm Handling 27

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x08000005 Failed to Read PCIe Card Temperature (PCIe Card, Minor Alarm)

ALM-0x08000005 Failed to Read PCIe Card Temperature (PCIe Card, Minor Alarm)

Description

Alarm message (iBMC versions earlier than V308):

Failed to obtain data of the arg1 arg2 arg3 temperature.

Alarm message (iBMC V308 or later):

Failed to obtain data of the arg1 arg2 arg3 temperature. [arg4] [arg5]
NOTE:

From iBMC V316, the CPU and disk alarms will also include the SN and part umber and the mainboard and memory alarms will also include the part number.

This alarm is generated when the system failed to obtain the PCIe card temperature.

Alarm object: PCIe card

Attribute

Alarm ID Alarm Severity Auto Clear

0x08000005

Minor

Yes

Parameters

Name Meaning
arg1

Location of the PCIe card. For example, GpuBoard or Riser.

arg2

Slot number of the PCIe card, for example, 1 or 2.

arg3

Type of the PCIe card, for example, FPGA Chip or Hi1822 Optical Module.

arg4

Supplementary information about the alarm, for example, Error Code.

NOTE:
This parameter is available only for iBMC V308 and later versions.
arg5

Error code of the alarm, for example, (7001).

NOTE:
This parameter is available only for iBMC V308 and later versions.

Impact on the System

The temperature cannot be monitored. No alarm will be reported when the temperature is not in the normal range. Fan adjustment is affected.

Possible Causes

The sensor chip has failed or the sensor access channel is unavailable.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 2.

  2. Shut down the OS and then restart it. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Remove and reinstall the power cable or board. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  4. Replace the PCIe card. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 5.

  5. Contact Huawei technical support.