Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x44000001 Logical Drive Degraded, Partially Degraded, or Offline (Logical Drive, Major Alarm)

ALM-0x44000001 Logical Drive Degraded, Partially Degraded, or Offline (Logical Drive, Major Alarm)

Description

Alarm message:

The logical drive arg1 under RAID card arg2 is arg3.

This alarm is generated when the logical drive of the RAID controller card is degraded, partially degraded, or offline.

Alarm object: Logical Drive

Attribute

Alarm ID Alarm Severity Auto Clear

0x44000001

Major

Yes

Parameters

Name Meaning

arg1

ID of the logical drive, for example, 1 or 2.

arg2

Slot number and location of the RAID controller card, for example, 1 and PCIe Card 3 (RAID).

arg3

Local drive status, for example, degraded, partially degraded, or offline

Impact on the System

The fault of the RAID controller card degrades the RAID or causes data loss.

Possible Causes

Member drives of the RAID are removed.

Procedure

  1. Check whether the RAID array has member drives removed.

    • If no, go to 2.

    • If no, go to 3.

  2. Reinstall the hard disk and check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Replace the hard disk that causes the RAID controller card failure, and then check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  4. Contact Huawei technical support.