No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FusionServer Pro Rack Server iBMC Alarm Handling 30

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2C00000D No Memory Detected During POST (System, Critical Alarm)

ALM-0x2C00000D No Memory Detected During POST (System, Critical Alarm)

Description

Alarm message:

No memory detected. 

This alarm is generated during BIOS startup when any of the following occurs:

  • No DIMM is detected.
  • The only DIMM is faulty.
  • The only DIMM is installed in an incorrect position.

Alarm object: system

Attribute

Alarm ID Alarm Severity Auto Clear

0x2C00000D

Critical

Yes

Parameters

Name Meaning

-

-

Impact on the System

The server cannot start.

Possible Causes

  • No DIMM is installed.
  • The only DIMM is faulty and therefore isolated by the BIOS.
  • The only DIMM is installed in an incorrect position.

Procedure

  1. Check the CPU and DIMM models.
  2. Use Intelligent Computing Compatibility Checker to check whether the CPUs and DIMMs are compatible with the server.

    • If yes, go to 4.

    • If no, go to 3.

  3. Replace the DIMMs with the ones that are compatible with the server and CPUs. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 5.

  4. Check whether the server is configured with the DIMMs of the same model.

    • If yes, go to 5.

    • If no, go to 6.

  5. Use the DIMMs of the same model. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 6.

  6. Replace the mainboard. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 7.

  7. Contact Huawei technical support.
Download