Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0142FFFF Below Lower Major Threshold (SYS 5V)

ALM-0x0142FFFF Below Lower Major Threshold (SYS 5V)

Description

Alarm message:

Below lower major threshold

This alarm is generated when the SYS 5V voltage detected by the HFC of the RH8100 V3 is lower than the major threshold.

Sensor triggering the alarm: SYS 5V

Attribute

Alarm ID Alarm Severity Auto Clear

0x0142FFFF

Major

Yes

Impact on the System

The server may be powered off abnormally.

Possible Causes

The HFC is faulty.

Procedure

  1. Remove and reinstall the HFC. Then check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 2.

  2. Replace the HFC. Then check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Contact Huawei technical support.