FusionServer Pro Rack Server iBMC Alarm Handling 30

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x02000025 Hard Disk Link Fault (Disk, Major Alarm)

ALM-0x02000025 Hard Disk Link Fault (Disk, Major Alarm)

Description

Alarm message:

The arg1 arg2 arg3 link is faulty (SN: arg4, PN: arg5). 
NOTE:

From iBMC V316, the CPU and disk alarms will also include the SN and part umber and the mainboard and memory alarms will also include the part number.

This alarm is generated when a hard disk link fault is detected.

Alarm object: disk

Attribute

Alarm ID Alarm Severity Auto Clear

0x02000025

Major

Yes

Parameters

Name Meaning

arg1

Hard disk location, for example FIO.

arg2

Hard disk slot No., for example DISK1.

arg3

Type of the hard disk link, for example PCIe.

arg4

Disk serial number.

arg5

Part number.

Impact on the System

The hard disk cannot be used.

Possible Causes

The hard disk link is faulty.

Procedure

  1. Check whether the hard disk is properly installed.

    • If yes, go to 3.

    • If no, go to 2.

  2. Remove and reinstall the hard disk. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Check whether the NVMe or SAS cables are correctly connected.

    For details about the cable connection sequence, see the user guide of the server you use.

    • If yes, go to 5.

    • If no, go to 4.

  4. Connect the NVMe or SAS cables correctly. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 5.

  5. Replace the NVMe or SAS cable. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 6.

  6. Replace the hard disk backplane or adapter card. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 7.

  7. Replace the CPU. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 8.

  8. Replace the mainboard. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 9.

  9. Contact Huawei technical support.
Download
Updated: 2019-08-05

Document ID: EDOC1000054724

Views: 335125

Downloads: 3066

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next