Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x02000009 Hard Disk Prewarning (Disk, Minor Alarm)

ALM-0x02000009 Hard Disk Prewarning (Disk, Minor Alarm)

Description

Alarm message:

The [arg1] disk arg2 predictive failure (SN: arg3, PN: arg4).
NOTE:

From iBMC V316, the CPU and disk alarms will also include the SN and part umber and the mainboard and memory alarms will also include the part number.

This alarm is generated when the number of hard disk errors reached the prewarning threshold.

NOTE:

If arg2 is DISKA, DISKB, DISKC, or DISKD, this alarm is generated for the rear hard disk of a V2 or V3 server. For details about the slot information of the hard disks on a V3 server, see "Removing a Hard Disk" in the user guide of the server you use.

Alarm object: disk

NOTE:

This alarm also applies to SATADOM and M.2 disks.

Attribute

Alarm ID Alarm Severity Auto Clear

0x02000009

Minor

Yes

Parameters

Name Meaning

arg1

Location of the hard disk. For example, FM or CMn.

arg2

Slot number of the hard disk.

arg3

Disk serial number.

arg4

Part number.

Impact on the System

The hard disk reliability decreases, affecting the OS storage performance and services.

Possible Causes

  • The hard disk is in read-only mode.
  • The number of hard disk SMART errors detected exceeds the threshold.
  • The NVMe remaining service life is about to expire.

Procedure

  1. When this alarm is generated, server operation remains unaffected. Replace the faulty hard disk when convenient. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 2.

  2. Contact Huawei technical support.