No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Huawei Rack Server iBMC Alarm Handling 28

This document describes iBMC alarms in terms of the meaning, impact on the system, possible causes, and handling suggestions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x1000006F Failed to Read Standby 3.3 V Voltage (Mainboard, Minor Alarm)

ALM-0x1000006F Failed to Read Standby 3.3 V Voltage (Mainboard, Minor Alarm)

Description

Alarm message:

Failed to obtain the voltage at standby 3.3 V detection point on the mainboard (PN: arg1).
NOTE:

From iBMC V316, the CPU and disk alarms will also include the SN and part umber and the mainboard and memory alarms will also include the part number.

This alarm is generated when the system failed to obtain the voltage at standby 3.3 V detection point.

Alarm object: mainboard

Attribute

Alarm ID Alarm Severity Auto Clear

0x1000006F

Minor

Yes

Parameters

Name Meaning
arg1

Part number.

Impact on the System

The voltage cannot be monitored. No alarm will be reported when the voltage is not in the normal range.

Possible Causes

  • The iBMC is faulty.
  • The mainboard is faulty.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 2.

  2. Remove and reinstall the power cable or board. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 3.

  3. Replace the mainboard. Then, check whether the alarm is cleared.

    • If yes, no further action is required.

    • If no, go to 4.

  4. Contact Huawei technical support.
Download
Updated: 2019-06-04

Document ID: EDOC1000054724

Views: 242382

Downloads: 2949

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next